Literature DB >> 25002050

Forensic DNA typing strategy of degraded DNA on discarded cigarette ends using the AmpFℓSTR® Identifiler®, Identifiler® Plus and MiniFiler™ PCR amplification kits.

Stephen C Y Ip1, Sze-wah Lin2, Christina Li2, Kam-ming Lai2.   

Abstract

DNA left on a forensic sample is often prone to degradation, especially if left to the elements. To maximize the chance of retrieving the most information from such compromised DNA, an appropriate profiling scheme using the available technologies needs to be devised. In this study, a total of 62 cigarette ends collected under different conditions of environmental exposure were employed to test the effectiveness of three DNA amplification kits, namely the Applied Biosystems™ AmpFℓSTR® Identifiler®, Identifiler® Plus and MiniFiler™ PCR Amplification Kits, in the profiling of such compromised DNA. We demonstrated that Identifiler® Plus could substitute Identifiler® to improve the effectiveness of profiling for those inhibited cigarette samples. MiniFiler™, on the other hand, could supplement Identifiler®/Identifiler® Plus profiles and provide additional genetic information to enhance the evidential value of the samples, especially for those that have suffered from DNA degradation to a greater extent. The findings in this work allowed us to propose a DNA profiling strategy as follow: 1) samples yielding complete Identifiler®/Identifiler® Plus profiles require no further testing with MiniFiler™; 2) samples yielding partial single-source profiles to be tested with MiniFiler™ to add genetic information; 3) samples yielding no results are unlikely to yield any results with MiniFiler™.
Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

Keywords:  Cigarette end; Degradation; Identifiler; Identifiler Plus; Inhibition; MiniFiler

Mesh:

Year:  2014        PMID: 25002050     DOI: 10.1016/j.scijus.2014.04.007

Source DB:  PubMed          Journal:  Sci Justice        ISSN: 1355-0306            Impact factor:   2.124


  3 in total

1.  Developmental validation of the STRscan-17LC kit: a 6 Dye STR kit enhanced stability and ability to detect degraded samples.

Authors:  Bowei Jiang; Wei He; Chuan Jin; Ying Liu; Dan Wen; Chudong Wang; Moutanou Modeste Judes Zeye; Jienan Li; Lagabaiyila Zha
Journal:  Int J Legal Med       Date:  2021-01-16       Impact factor: 2.686

2.  Utility of Circulating Cell-Free DNA in Assessing Microsatellite Instability and Loss of Heterozygosity in Breast Cancer Using Human Identification Approach.

Authors:  Norah A Al Sharhan; Safia A Messaoudi; Saranya R Babu; AbdulRauf B Chaudhary; Abdullah A Alsharm; Abdulmajeed F Alrefaei; Sultan Kadasah; Muhammad Abu-Elmagd; Mourad Assidi; Abdelbaset Buhmeida; Ángel Carracedo; Wassim Y Almawi
Journal:  Genes (Basel)       Date:  2022-03-25       Impact factor: 4.141

3.  Forensic STR profiling based smart barcode, a highly efficient and cost effective human identification system.

Authors:  Andleeb Zahra; Bilal Hussain; Amer Jamil; Z Ahmed; Shahid Mahboob
Journal:  Saudi J Biol Sci       Date:  2018-10-02       Impact factor: 4.219

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.