Literature DB >> 24998837

Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms.

Bernardo C Mendes1, Gustavo S Oderich2, Thanila A Macedo3, Alexandre A Pereira1, Stephen Cha4, Audra A Duncan1, Peter Gloviczki1, Thomas C Bower1.   

Abstract

OBJECTIVE: The objective of this study was to evaluate the anatomic feasibility of two off-the-shelf fenestrated stent graft designs to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs).
METHODS: Digital computed tomography angiograms were analyzed in 520 consecutive patients treated by open or fenestrated endovascular repair for complex AAAs (2000-2012). The anatomic feasibility of two off-the-shelf fenestrated designs, Endologix Ventana (Endologix Inc, Irvine, Calif) and Cook p-Branch (Cook Medical, Brisbane, Australia), was analyzed with the instructions for use (IFU) proposed by investigational protocols.
RESULTS: There were 390 patients (75%) with juxtarenal and pararenal AAAs considered potential candidates for one of the two devices. Proximal seal (>15 mm) was achieved in all patients with the p-Branch and in 61% of the patients with the Ventana stent graft (P < .0001). The ability to incorporate visceral arteries was greater with the Ventana (90% vs 61%) compared with the p-Branch design (P < .0001). Less than a third of patients met strict IFU criteria with Ventana (27%) or p-Branch (33%; P < .05). By liberal IFU criteria, 42% of patients were candidates for Ventana and 49% for p-Branch (P < .03). Overall, 63% of the patients with juxtarenal and pararenal AAAs were candidates for endovascular repair with one of the two devices.
CONCLUSIONS: The p-Branch design has greater anatomic feasibility and achieves proximal seal in all patients with juxtarenal and pararenal AAAs but is not able to incorporate visceral arteries in 40% of patients. The Ventana design allows incorporation of the visceral arteries in 90% of patients but fails to provide sufficient seal in 40%. Nearly 40% of juxtarenal and pararenal AAAs do not meet anatomic criteria for endovascular repair with one of the two devices, justifying the need for additional designs.
Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24998837     DOI: 10.1016/j.jvs.2014.04.038

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  5 in total

1.  'In-stock' fenestrated stent graft for the urgent repair of an abdominal aortic aneurysm.

Authors:  Sean A Crawford; Matthew G Doyle; Leonard W Tse; Graham Roche-Nagle
Journal:  BMJ Case Rep       Date:  2016-05-20

Review 2.  The Current State of Fenestrated and Branched Devices for Abdominal Aortic Aneurysm Repair.

Authors:  Holly L Graves; Benjamin M Jackson
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

3.  Systematic Review and Meta-Analysis of Published Studies on Endovascular Repair of Abdominal Aortic Aneurysm With the p-Branch.

Authors:  Haoliang Wu; Liwei Zhang; Mingxing Li; Shunbo Wei; Cong Zhang; Hualong Bai
Journal:  Front Surg       Date:  2022-04-29

Review 4.  Fenestrated Endovascular Aneurysm Repair versus Snorkel Endovascular Aneurysm Repair: Competing yet Complementary Strategies.

Authors:  William J Yoon
Journal:  Vasc Specialist Int       Date:  2019-09-30

5.  Emergency Endovascular Repair of Symptomatic Post-dissection Thoraco-abdominal Aneurysm Using a Physician Modified Fenestrated Endograft During the Waiting Period for a Manufactured Endograft.

Authors:  Aleem K Mirza; Jussi M Kärkkäinen; Emanuel R Tenorio; Guilherme B Lima; Giuliana B Marcondes; Gustavo S Oderich
Journal:  EJVES Vasc Forum       Date:  2020-09-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.