Literature DB >> 24997368

Reversible detection of vancomycin using peptide-functionalized cantilever array sensor.

Xiaojing Bai1, Baoping Lu1, Xuejuan Chen1, Bailin Zhang2, Jilin Tang3.   

Abstract

A reversible detection method for vancomycin was developed utilizing the cantilever array sensor functionalized by a designed peptide consisting of a cysteine (Cys-), a space linker (-Gly-Gly-Gly-Gly-) and a molecular recognition ligand (-L-Lys-D-Ala-D-Ala). It was found that the peptide space linker was necessary and important for the response of the cantilever array sensor. The sensing cantilevers in the array were functionalized with the peptide while the reference cantilevers were modified by 6-mercapto-1-hexanol (MCH) to eliminate the influence of environmental disturbances. The binding between vancomycin and the peptide induced a change of surface stresses in the sensing cantilevers resulting in a differential deflection between the sensing and reference cantilevers. The reciprocal of the differential deflection is linear with the reciprocal of vancomycin concentration within the range of 2 μM to 100 μM (R=0.993) at a detection limit of 0.2 μM (S/N=3). The reversible detection can be realized just by regenerating the sensing cantilevers with running buffer solution. Other antibiotics such as doxycycline, streptomycin, and kanamycin have negligible effect on the response of the sensor. The sensor can also be utilized for reversible detection of vancomycin in serum background, which clearly indicates the potential of the sensor for vancomycin detection in real biological samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cantilever array sensor; Peptide; Reversibility; Serum; Vancomycin

Mesh:

Substances:

Year:  2014        PMID: 24997368     DOI: 10.1016/j.bios.2014.06.024

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A poly(acrylic acid)-modified copper-organic framework for electrochemical determination of vancomycin.

Authors:  Atal A S Gill; Sima Singh; Nikhil Agrawal; Zondi Nate; Tirivashe E Chiwunze; Neeta Bachheti Thapliyal; Ruchika Chauhan; Rajshekhar Karpoormath
Journal:  Mikrochim Acta       Date:  2020-01-02       Impact factor: 5.833

2.  Multiscale Simulation of Adsorption Based Microcantilever Biosensors for Radiation Exposure Effects.

Authors:  Fouad Mollaei; Peiman Aliparast; Abolghasem Naghash
Journal:  Iran J Biotechnol       Date:  2020-04-01       Impact factor: 1.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.