A 7-year prospective radiographic evaluation of marginal bone level around two different implant systems: a randomized clinical trial.

Doris Burtscher1, Burkhard Norer2, Daniel Dalla Torre2, Ulrike Beier1, Katharina Schubert1, Ingrid Grunert1.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the change in marginal bone level radiographically around two different implant systems after 7 years of use.
MATERIAL AND METHODS: Twenty fully edentulous patients were included in the study and randomly assigned to two treatment groups of machined surface implants (Brånemark, n = 40) and rough-surface implants (Xive, n = 40). The implants were early loaded with individual bar-retained overdentures. All patients were treated by the same surgeon and the same prosthodontist. Clinical and radiographic examinations were conducted at the time of implant loading (baseline) and annually for up to 7 years of use. Measurements to the nearest 0.1 mm were taken at the mesial and distal site, and the average values were calculated for each implant. A three-level mixed-effect analysis of covariance (ANOVA) was used to test the significance of the mean marginal bone change in the two implant groups.
RESULTS: The study population consisted of 15 women (75%) and five men (25%) with an average age of 61.6 years. A total of 79 of 80 implants integrated successfully. n = 1 Brånemark implant failed after 3 weeks. There was a significant difference (P < 0.001) between the two implant systems at the baseline measurements (0.14 mm Brånemark vs. 0.39 mm Xive) and a highly significant difference for the annual bone loss (0.07 mm [Brånemark] vs. 0.18 mm [Xive], P < 0.001).
CONCLUSION: Both the implant systems are clinically satisfying. Nevertheless, the Brånemark group showed a better radiological performance than the Xive group.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Brånemark; Xive; implant; machined surface; marginal bone level; radiographic

Mesh:

Substances:

Year:  2014        PMID: 24995411     DOI: 10.1111/clr.12444

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Marginal Bone Level Evaluation after Functional Loading Around Two Different Dental Implant Designs.

Authors:  Ko-Ning Ho; Eisner Salamanca; Hsi-Kuai Lin; Sheng-Yang Lee; Wei-Jen Chang
Journal:  Biomed Res Int       Date:  2016-11-24       Impact factor: 3.411

2.  Sandblasting reduces dental implant failure rate but not marginal bone level loss: A systematic review and meta-analysis.

Authors:  László Márk Czumbel; Beáta Kerémi; Noémi Gede; Alexandra Mikó; Barbara Tóth; Dezső Csupor; Andrea Szabó; Sándor Farkasdi; Gábor Gerber; Márta Balaskó; Erika Pétervári; Róbert Sepp; Péter Hegyi; Gábor Varga
Journal:  PLoS One       Date:  2019-05-03       Impact factor: 3.240

3.  Influence of different incision designs on bone increment of guided bone regeneration (Bio-Gide collagen membrane +Bio-OSS bone powder) during the same period of maxillary anterior tooth implantation.

Authors:  Genying Zhuang; Jianshui Mao; Guoli Yang; Huiming Wang
Journal:  Bioengineered       Date:  2021-12       Impact factor: 3.269

  3 in total