Literature DB >> 24994546

Usefulness of postmarket studies to evaluate long-term safety of coronary eluting stents (from the ENDEAVOR and PROTECT Programs).

Moshe Vardi1, Jeremiah Perez2, Paula J Griffin2, David A Burke3, Robert W Yeh4, Donald E Cutlip3.   

Abstract

Differences in enrollment criteria and protocol requirements are believed to affect patient representation and outcomes from premarket and postmarket surveillance (PMS) trials. These differences have not been assessed in studies evaluating coronary stenting. We aimed to assess differences in clinical profile and long-term outcomes in patients enrolled into premarket versus PMS trials assessing the Endeavor zotarolimus-eluting stent (E-ZES). We pooled patient-level data for 2,132 and 4,357 E-ZES-treated subjects enrolled into the ENDEAVOR program (premarket) and Patient Related OuTcomes with Endeavor versus Cypher stenting Trial (PMS), respectively. Follow-up data were available through 3 years. Baseline characteristics and outcomes of patients enrolled in the 2 groups were compared. Propensity score-adjusted Cox proportional hazards models were used to assess the effect of differences in baseline characteristics. We also adjusted for protocol-mandated repeat angiography to account for differences in follow-up requirements. Despite significant differences in baseline characteristics, the unadjusted 3-year rates of major adverse cardiac events, major adverse cardiac and cerebrovascular events, and target vessel failure were similar (premarket vs PMS: 11.9% vs 12.7%, p = 0.369; 12.7% vs 13.9%, p = 0.191; and 13.8% vs 13.4%, p = 0.667, respectively). However, PMS trials had significantly higher rates of myocardial infarctions (p = 0.005) and definite or probable stent thrombosis (p = 0.016). After propensity score adjustment, myocardial infarction rates remained significantly different (hazard ratio 0.53, 95% confidence interval 0.30 to 0.91). To conclude, premarket and PMS trials assessing E-ZES implantation enrolled different patients. PMS trials were shown to be essential for the detection of safety signals.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24994546     DOI: 10.1016/j.amjcard.2014.05.028

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Analysis of the safety evaluation for premarketing clinical trials of hemodialyzer and of postmarketing safety reports of hemodialyzer in Japan and the US: insights into the construction of a sophisticated premarketing evaluation.

Authors:  Masami Saito; Kiyotaka Iwasaki
Journal:  J Artif Organs       Date:  2016-10-05       Impact factor: 1.731

2.  Medical device postapproval safety monitoring: where does the United States stand?

Authors:  Prashant V Rajan; Daniel B Kramer; Aaron S Kesselheim
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2015-01-06
  2 in total