Literature DB >> 24992237

[Reliable UV-light protection in intraocular lenses--scientific rationale and quality requirements].

A J Augustin1.   

Abstract

Since the late 1980s implantation of UV-blocker intraocular lenses during cataract surgery has become an internationally accepted standard. Last year the Kassenärztliche Vereinigung Bayern (KVB) and statutory health insurance organisations proposed for the first time quality criteria for intraocular lenses (IOL), thereby including exact parameters for the amount of UV light transmission (≤10% at 400 nm). Since then, the discussion has been raised again as to what extent IOLs should filter or block UV light. In this article, exact definitions of spectral subbands within the optical radiation band are given. Today, 400 nm is the internationally accepted standard to distinguish UV light and visible light. Moreover, exposure of the eye to UV radiation is described as well as mechanisms of photooxidative damage to the retina. Comprehensive laboratory and animal experimental studies show that light of short wave lengths, i.e., above all UV light but also blue light, may induce photochemical damage to the retina. Primary sites of such damage are both the outer segments of the photoreceptors and the retinal pigment epithelium (RPE). Physiological protective mechanisms of the eye, such as filtering properties of different ocular media are described in detail. Cornea, aqueous and vitreous absorb UV radiation below 300 nm, while the natural adult lens absorbs UV radiation between 300 and 400 nm. This protection is lost when the lens is removed by cataract surgery and thus should be restored. UV light does not contribute to vision but damages retinal structures. Therefore, UV-blocking intraocular lenses with a 10% cut-off near 400 nm should be implanted during cataract surgery. This ensures sufficient retinal protection after surgery. These theoretical considerations are supported by results from animal and clinical studies. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2014        PMID: 24992237     DOI: 10.1055/s-0034-1368566

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  4 in total

Review 1.  Phototoxicity of environmental radiations in human lens: revisiting the pathogenesis of UV-induced cataract.

Authors:  Farzin Kamari; Shahin Hallaj; Fatemeh Dorosti; Farbod Alinezhad; Negar Taleschian-Tabrizi; Fereshteh Farhadi; Hassan Aslani
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-06-21       Impact factor: 3.117

Review 2.  Ultraviolet or blue-filtering intraocular lenses: what is the evidence?

Authors:  S M Downes
Journal:  Eye (Lond)       Date:  2016-01-08       Impact factor: 3.775

Review 3.  The Molecular Mechanism of Retina Light Injury Focusing on Damage from Short Wavelength Light.

Authors:  Bin Fan; ChunXia Zhang; Jing Chi; Yang Liang; XiaoLi Bao; YunYi Cong; Bo Yu; Xun Li; Guang-Yu Li
Journal:  Oxid Med Cell Longev       Date:  2022-04-19       Impact factor: 7.310

4.  Non-Contact Optical Detection of Foreign Materials Adhered to Color Filter and Thin-Film Transistor.

Authors:  Fu-Ming Tzu; Shih-Hsien Hsu; Jung-Shun Chen
Journal:  Micromachines (Basel)       Date:  2022-01-08       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.