Contact allergy to epoxy hardeners.

Kristiina Aalto-Korte1, Katri Suuronen, Outi Kuuliala, Maj-Len Henriks-Eckerman, Riitta Jolanki.   

Abstract

BACKGROUND: Diglycidylether of bisphenol A resin is the most important sensitizer in epoxy systems, but a minority of patients develop concomitant or solitary contact allergy to epoxy hardeners. At the Finnish Institute of Occupational Health, several in-house test substances of epoxy hardeners have been tested in a special epoxy compound patch test series.
OBJECTIVES: To analyse the frequency and clinical relevance of allergic reactions to different epoxy hardeners.
METHODS: Test files (January 1991 to March 2013) were screened for contact allergy to different epoxy hardeners, and the clinical records of patients with allergic reactions were analysed for occupation, concomitant allergic reactions, and exposure.
RESULTS: The most commonly positive epoxy hardeners were m-xylylenediamine (n = 24), 2,4,6-tris-(dimethylaminomethyl)phenol (tris-DMP; n = 14), isophorone-diamine (n = 12), and diethylenetriamine (n = 9). Trimethylhexamethylenediamine (n = 7), tetraethylenepentamine (n = 4), and triethylenetetramine (n = 2) elicited some reactions, although most patients were found to have no specific exposure. Allergic reactions to hexamethylenetetramine, dimethylaminopropylamine and ethylenediamine dihydrochloride were not related to epoxy products.
CONCLUSIONS: Tris-DMP is an important sensitizer in epoxy hardeners, and should be included in the patch test series of epoxy chemicals.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  2,4,6-tris-(dimethylaminomethyl)phenol; CAS no. 90-72-2; diethylenetriamine; isophoronediamine; m-xylylenediamine; tetraethylenepentamine; triethylenetetramine; trimethylhexamethylenediamine

Mesh:

Substances:

Year:  2014        PMID: 24990536     DOI: 10.1111/cod.12280

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  2 in total

1.  [Contact allergies in the German workforce : Data of the IVDK network from 2003-2013].

Authors:  A Bauer; J Geier; V Mahler; W Uter
Journal:  Hautarzt       Date:  2015-09       Impact factor: 0.751

2.  Characterization of patients with occupational allergy to two new epoxy hardener compounds.

Authors:  Sari Suomela; Maria Pesonen; Katriina Ylinen; Kristiina Aalto-Korte; Katri Suuronen
Journal:  Contact Dermatitis       Date:  2022-04-19       Impact factor: 6.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.