| Literature DB >> 24988209 |
Tomoyuki Hayashi1, Hisashi Doyama1, Yukihiro Shirota2, Hirokazu Tsuji3, Youhei Marukawa4, Hajime Ohta4, Kazuhiro Miwa5, Takaharu Masunaga6, Shuichi Terasaki7, Yutaka Matano8, Kunihiro Tsuji9, Yoshibumi Kaneko10, Toshihide Okada1, Hiroshi Kurumaya11, Shuichi Kaneko12.
Abstract
OBJECTIVES: Magnifying narrow-band imaging (M-NBI) is more accurate than white-light imaging for diagnosing small gastric cancers. However, it is uncertain whether moving M-NBI images have additional effects in the diagnosis of gastric cancers compared with still images.Entities:
Mesh:
Year: 2014 PMID: 24988209 PMCID: PMC4079511 DOI: 10.1371/journal.pone.0100857
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Flow chart of enrollment and analysis records.
Characteristics of 40 Gastric Lesions Used in Both Tests.
| No. | % | |||
| Histological type | Cancer | 21 | 52.5 | |
| Well differentiated adenocarcinoma | 17 | 42.5 | ||
| Moderately differentiated adenocarcinoma | 4 | 10.0 | ||
| Noncancer | 19 | 47.5 | ||
| Low-grade adenoma | 2 | 5.0 | ||
| Chronic gastritis | 16 | 40.0 | ||
| Xanthoma | 1 | 2.5 | ||
| Elevation | Yes | 10 | 25.0 | |
| No | 30 | 75.0 | ||
| Tumor location | Upper | 5 | 12.5 | |
| Middle | 18 | 45.0 | ||
| Lower | 17 | 42.5 | ||
| Size | <10 mm | 21 | 52.5 | |
| ≥10 mm | 19 | 47.5 |
Figure 2Cancerous lesion: Within a DL (arrows), irregular MVP and irregular MSP are noted.
Figure 3Non-cancerous lesion (gastritis): Absent DL, regular MVP, and regular MSP are noted.
M-NBI findings of 40 Gastric Lesions Used in Both Tests.
| No. | % | ||
| Demarcation Line | Present | 30 | 75.0 |
| Absent | 10 | 25.0 | |
| Microvascular pattern | Regular | 14 | 35.0 |
| Irregular | 21 | 52.5 | |
| Absent | 5 | 12.5 | |
| Microsurface pattern | Regular | 14 | 35.0 |
| Irregular | 20 | 50.0 | |
| Absent | 6 | 15.0 |
Diagnostic Accuracy, Sensitivity, and Specificity of Cancerous versus Noncancerous Lesions of Still Image Test versus Moving Image Test in Overall 34 Endoscopists.
| Still Image Test, % [95% C.I.] | Moving Image Test, % [95% C.I.] |
| |
| Accuracy | 59.9 [56.1–63.6] | 61.5 [57.1–65.8] | .272 |
| Sensitivity | 53.4 [48.0–58.7] | 55.9 [49.2–62.6] | .312 |
| Specificity | 67.0 [61.9–72.1] | 67.6 [61.4–73.8] | .812 |
Endoscopic Diagnoses for All Lesions according to Grade of Certainty in Still and Moving Image Tests.
| Still Image Test | Moving Image Test | |||||
| Grade | Cancer | Non-cancer | Total | Cancer | Non-cancer | Total |
| 1 | 66 | 141 | 207 | 55 | 123 | 178 |
| 2 | 163 | 186 | 349 | 161 | 218 | 379 |
| 3 | 104 | 106 | 210 | 98 | 96 | 194 |
| 4 | 265 | 159 | 424 | 265 | 158 | 423 |
| 5 | 116 | 54 | 170 | 135 | 51 | 186 |
| Total | 714 | 646 | 1360 | 714 | 646 | 1360 |
*Grade 1: “noncancerous,” with high degree of confidence; grade 2: “noncancerous,” with low degree of confidence; grade 3: “indeterminate,” classified as “noncancerous”; grade 4: “cancerous,” with low degree of confidence; grade 5: “cancerous,” with high degree of confidence.
Figure 4Receiver operating characteristic (ROC) curve of the endoscopic diagnostic grades is according to the certainty of each test correlated with sensitivity and (1 – specificity).
The area under the curve (AUC) was as follows: still image test 0.629, moving image test 0.649 (P = 0.303).
Diagnostic Accuracy of Vessels Plus Surface Classification System in Still Image Test versus Moving Image Test by All 34 Endoscopists.
| Accuracy, % [95% C.I.] |
| ||
| Still Image Test | Moving Image Test | ||
| Demarcation Line | 65.4 [62.0–68.9] | 65.5 [61.4–69.6] | .955 |
| Microvascular pattern | 56.7 [52.7–60.8] | 56.9 [53.2–60.6] | .866 |
| Microsurface pattern | 48.1 [44.5–51.8] | 50.9 [46.6–55.1] | .115 |
Diagnostic Accuracy of Still Image Test versus Moving Image Test in the Subgroups of Endoscopic Findings.
| Accuracy, % [95% C.I.] |
| |||
| Subgroup | Still Image Test | Moving Image Test | ||
| Elevation | Yes (n = 10) | 57.9 [40.6–75.3] | 60.3 [46.6–74.0] | .389 |
| No (n = 30) | 60.5 [52.6–68.4] | 61.9 [53.8–69.9] | .405 | |
| Tumor location | Upper (n = 5) | 65.3 [38.8–91.8] | 67.1 [45.5–88.6] | .646 |
| Middle (n = 18) | 57.7 [47.6–67.7] | 59.2 [48.6–69.7] | .630 | |
| Lower (n = 17) | 60.6 [48.1–73.0] | 62.3 [51.1–73.5] | .538 | |
| Size | <10 mm (n = 21) | 62.6 [53.6–71.6] | 65.8 [57.3–74.4] | .228 |
| ≥10 mm (n = 19) | 56.8 [45.3–68.3] | 56.7 [46.0–67.3] | .951 | |
Diagnostic Accuracy of Still Image Test versus Moving Image Test in the Subgroups of Endoscopist Characteristics.
| Accuracy, % [95% C.I.] |
| |||
| Subgroup | Still Image Test | Moving Image Test | ||
| Board-Certified by JGES | Yes (n = 15) | 62.7 [58.5–66.8] | 66.5 [62.8–70.2] | .041 |
| No (n = 19) | 57.8 [51.9–63.6] | 57.5 [50.5–64.5] | .908 | |
| Years of experience performing upper gastrointestinal endoscopy | ≥8 (n = 17) | 62.6 [59.2–66.1] | 65.2 [61.2–69.4] | .161 |
| <8 (n = 17) | 57.2 [50.5–63.9] | 57.6 [49.9–65.4] | .856 | |
| Number of cases of upper gastrointestinal endoscopy | ≥5000 (n = 20) | 61.9 [57.1–66.6] | 64.5 [59.8–69.2] | .112 |
| <5000 (n = 14) | 57.1 [50.9–63.4] | 57.1 [48.7–65.6] | >.999 | |
| Number of cases of M-NBI procedures | ≥200 (n = 18) | 65.6 [60.4–70.7] | 68.9 [64.2–73.6] | .049 |
| <200 (n = 16) | 53.6 [50.1–57.1] | 53.1 [47.7–58.5] | .858 | |
| Number of cases of M-NBI procedures in the previous month | ≥15 (n = 15) | 65.2 [58.8–71.5] | 69.3 [63.2–75.5] | .037 |
| <15 (n = 19) | 55.7 [52.0–59.5] | 55.3 [50.5–60.0] | .811 | |
*Japan Gastroenterological Endoscopy Society.