| Literature DB >> 24987734 |
Feyza Ulkur1, Elif Sungurtekin Ekçi2, Didem Nalbantgil1, Nuket Sandalli2.
Abstract
The aim of this in vitro was to evaluate the effects of tricalcium phosphate (TCP) and amorphous calcium phosphate (ACP) containing varnish materials and Er:YAG laser irradiation on enamel demineralization around orthodontic brackets. Forty extracted human premolar teeth were randomly divided into four treatment groups (i.e., 10 in each group): (1) 5% NaF-ACP varnish, (2) 5% NaF-TCP varnish, (3) Er:YAG laser, and (4) control (no treatment). Er:YAG laser was operated at a wavelength of 2.94 μm and the energy output was 80 mJ per pulse; a pulse duration of 200 μsec and and a frequency of 2 Hz were used with water cooling. All samples were then put into pH cycles. Surface microhardness values and representative SEM images were assessed. Surface microhardness values were evaluated using Kruskal-Wallis and Mann-Whitney U tests. The results revealed that demineralization was significantly lower in the TCP and ACP varnish groups, whereas mean surface microhardness values of the TCP varnish were found higher than the ACP (P < 0.05). TCP and ACP varnish materials were found effective for reducing enamel demineralization around orthodontic brackets. Use of Er:YAG laser irradiation as described in this study for inhibition of demineralization was found not satisfactory.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24987734 PMCID: PMC4058603 DOI: 10.1155/2014/490503
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Figure 1Positions and depths of indentations.
Multiple comparisons of microhardness values of specimens from 3 positions and 5 depths from the coronal side of bracket surface.
| Distances from bracket surface | Depths | Er:YAG laser group | Control group | TCP group | ACP group |
| ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | SD | Mean | SD | |||
| 0 | 10 | 331.31 | 25.64 | 323.81 | 31.48 | 362.83 | 37.95 | 351.42 | 24.60 | 0.009* |
| 20 | 335.90 | 26.42 | 323.91 | 20.89 | 378.53 | 23.12 | 355.36 | 20.47 | 0.000* | |
| 40 | 322.92 | 25.55 | 312.21 | 22.59 | 373.44 | 12.85 | 355.17 | 24.90 | 0.000* | |
| 70 | 306.69 | 22.51 | 291.20 | 26.20 | 356.37 | 16.32 | 330.87 | 25.43 | 0.000* | |
| 90 | 283.63 | 21.76 | 286.20 | 15.96 | 345.10 | 19.68 | 321.30 | 23.83 | 0.000* | |
|
| ||||||||||
| 100 | 10 | 358.05 | 14.52 | 350.14 | 17.76 | 393.68 | 11.28 | 364.23 | 6.15 | 0.000* |
| 20 | 359.67 | 14.78 | 348.88 | 29.11 | 392.84 | 10.88 | 370.85 | 7.64 | 0.000* | |
| 40 | 347.35 | 16.69 | 338.79 | 23.86 | 380.27 | 10.51 | 358.81 | 22.92 | 0.000* | |
| 70 | 327.77 | 17.69 | 313.54 | 31.97 | 367.99 | 11.41 | 329.78 | 25.81 | 0.000* | |
| 90 | 311.72 | 23.71 | 302.04 | 31.74 | 352.48 | 12.13 | 318.90 | 24.99 | 0.000* | |
|
| ||||||||||
| 200 | 10 | 361.07 | 10.87 | 331.81 | 30.32 | 392.05 | 10.54 | 356.75 | 15.67 | 0.000* |
| 20 | 356.66 | 13.52 | 338.37 | 16.48 | 385.45 | 13.96 | 353.79 | 18.20 | 0.000* | |
| 40 | 668.70 | 1042.84 | 320.36 | 30.06 | 367.85 | 12.02 | 348.08 | 18.67 | 0.002* | |
| 70 | 315.02 | 20.18 | 294.23 | 30.15 | 357.53 | 11.86 | 334.81 | 18.65 | 0.000* | |
| 90 | 289.22 | 34.87 | 276.30 | 28.59 | 344.01 | 13.13 | 318.49 | 24.44 | 0.000* | |
*P < 0.05: significance level; SD: standard deviation.
Post hoc statistical comparisons of microhardness values of specimens from 3 positions and 5 depths from the coronal side of bracket surface.
| Distances from bracket surface | 0 | 100 | 200 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Depths | 10 | 20 | 40 | 70 | 90 | 10 | 20 | 40 | 70 | 90 | 10 | 20 | 40 | 70 | 90 |
| Laser/control | 0.733 | 0.199 | 0.256 | 0.112 | 0.820 | 0.241 | 0.520 | 0.545 | 0.307 | 0.45 | 0.051 | 0.052 | 0.070 | 0.096 | 0.257 |
| Laser/TCP | 0.013 | 0.002* | 0.000* | 0.000* | 0.000* | 0.001* | 0.000* | 0.001* | 0.000* | 0.001* | 0.000* | 0.001* | 0.006* | 0.000* | 0.001* |
| Laser/ACP | 0.069 | 0.031 |
| 0.028 |
| 0.570 | 0.570 | 0.071 | 0.734 | 0.364 | 0.571 | 0.705 | 0.405 | 0.045 | 0.034 |
| Control/TCP | 0.008* | 0.001* | 0.000* | 0.000* | 0.000* | 0.000* | 0.000* | 0.001* | 0.000* | 0.000* | 0.000* | 0.000* | 0.001* | 0.000* | 0.000* |
| Control/ACP | 0.059 | 0.008* | 0.003* | 0.006* | 0.003* | 0.017 | 0.019 | 0.049 | 0.151 | 0.199 | 0.070 | 0.059 | 0.082 | 0.004* | 0.003* |
| TCP/ACP | 0.096 | 0.005* | 0.041 | 0.013 | 0.026 | 0.001* | 0.000* | 0.006* | 0.001* | 0.001* | 0.000* | 0.001* | 0.014 | 0.004* | 0.005* |
*P < 0.005: significance level.
Figure 2SEM images (1000x magnification) of the specimens from (a) Er:YAG laser, (b) control, (c) ACP, and (d) TCP.
Figure 3SEM images (2000x magnification) of the specimens from (a) Er:YAG laser, (b) control, (c) ACP, and (d) TCP.