Literature DB >> 24986742

Novel technique for hepatic fiducial marker placement for stereotactic body radiation therapy.

Hajer Jarraya1, Chloé Chalayer2, Emmanuelle Tresch3, Francois Bonodeau2, Thomas Lacornerie4, Xavier Mirabel4, Thomas Boulanger2, Sophie Taieb2, Andrew Kramar3, Eric Lartigau4, Luc Ceugnart2.   

Abstract

PURPOSE: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. METHODS AND MATERIALS: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside.
RESULTS: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method.
CONCLUSIONS: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24986742     DOI: 10.1016/j.ijrobp.2014.05.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Cholangiocarcinoma treatment with Synchrony-based robotic radiosurgery system: Tracking options.

Authors:  Debnarayan Dutta; Anjali Menon; Aswin George Abraham; Ram Madhavan; Haridas Nair; P G Shalet; J Jishan; Raghavendra Holla
Journal:  J Radiosurg SBRT       Date:  2018

2.  Stereotactic Body Radiation Therapy for the Management of Hepatocellular Carcinoma: Efficacy and Safety.

Authors:  Isaure Roquette; Emilie Bogart; Thomas Lacornerie; Massih Ningarhari; Jean-Emmanuel Bibault; Marie-Cecile Le Deley; Eric F Lartigau; David Pasquier; Xavier Mirabel
Journal:  Cancers (Basel)       Date:  2022-08-11       Impact factor: 6.575

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.