Literature DB >> 24986332

Reproducibility of a knee and hip proprioception test in healthy older adults.

Mina Arvin1, Marco J M Hoozemans, Bart J Burger, Sabine M P Verschueren, Jaap H van Dieën, Mirjam Pijnappels.   

Abstract

BACKGROUND: Proprioception can be assessed by measuring joint position sense (JPS). Most studies have focused on JPS of the knee joint while literature for other joints especially for hip JPS is scarce. Although some studies have evaluated proprioception of the knee joint, the reproducibility of methods has rarely been investigated. AIMS: To estimate intrasession reliability and agreement of an active-active JPS test for hip flexion/abduction and knee flexion in healthy older adults.
METHODS: Nineteen healthy older adults participated in this study. The proprioception of the hip (flexion and abduction) and knee (flexion) were assessed in both legs using the "active-active" reproduction technique. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and limits of agreement (LOA) were estimated for relative angular error (RE), absolute angular error (AE), and variable angular error (VE).
RESULTS: Reliability of our JPS test was substantial to almost perfect for the RE for both joints and legs (ICC values ranging from 0.75 to 0.93). We also found that the ICC values for AE were substantial for knee flexion and hip abduction of the left and right leg. The ICC results of VE showed poor reliability for hip and knee joints. SEM and LOA values for hip abduction were generally lower than for hip and knee flexion, indicating lower measurement error or more precise scores for the proprioception test of hip abduction. CONCLUSION(S): Proprioceptive acuity of the knee and hip joints in healthy older adults can be reliably assessed with an active-active procedure in a standing position with respect to relative and absolute error.

Entities:  

Mesh:

Year:  2014        PMID: 24986332     DOI: 10.1007/s40520-014-0255-6

Source DB:  PubMed          Journal:  Aging Clin Exp Res        ISSN: 1594-0667            Impact factor:   3.636


  11 in total

1.  Proprioceptive sensitivity to imposed finger deflections.

Authors:  Katie H Long; Kristine R McLellan; Maria Boyarinova; Sliman J Bensmaia
Journal:  J Neurophysiol       Date:  2022-01-12       Impact factor: 2.714

2.  Knee position sense: does the time interval at the target angle affect position accuracy?

Authors:  Shmuel Springer; Dor Kelman; Moshe Brand; Uri Gottlieb
Journal:  J Phys Ther Sci       Date:  2017-10-21

3.  Gait Stability and Its Influencing Factors in Older Adults.

Authors:  Daniel Hamacher; Dominik Liebl; Claudia Hödl; Veronika Heßler; Christoph K Kniewasser; Thomas Thönnessen; Astrid Zech
Journal:  Front Physiol       Date:  2019-01-24       Impact factor: 4.566

4.  Effects of knee orthoses on kinesthetic awareness and balance in healthy individuals.

Authors:  Nerrolyn Ramstrand; Terje Gjøvaag; Inger Marie Starholm; David F Rusaw
Journal:  J Rehabil Assist Technol Eng       Date:  2019-08-05

5.  Wireless Motion Sensors-Useful in Assessing the Effectiveness of Physiotherapeutic Methods Used in Patients with Knee Osteoarthritis-Preliminary Report.

Authors:  Jagoda Goślińska; Agnieszka Wareńczak; Margaret Miedzyblocki; Krystyna Hejdysz; Ewa Adamczyk; Paweł Sip; Ewa Chlebuś; Jarosław Gośliński; Piotr Owczarek; Adam Woźniak; Przemysław Lisiński
Journal:  Sensors (Basel)       Date:  2020-04-16       Impact factor: 3.576

6.  Bodyweight distribution between limbs, muscle strength, and proprioception in traumatic transtibial amputees: a cross-sectional study.

Authors:  Carlos Henrique da Silva Fontes Filho; Conrado Torres Laett; Ubiratã Faleiro Gavilão; José Carlos de Campos; Dângelo José de Andrade Alexandre; Victor R A Cossich; Eduardo Branco de Sousa
Journal:  Clinics (Sao Paulo)       Date:  2021-04-26       Impact factor: 2.365

7.  Active straight leg raising (ASLR) competence improves with reverse-ASLR exercises and not repeating ASLR exercises.

Authors:  Hiroshi Takasaki; Shota Kawazoe
Journal:  J Exerc Rehabil       Date:  2021-02-23

8.  Validity and Reliability of an Inertial Sensor-Based Knee Proprioception Test in Younger vs. Older Adults.

Authors:  Anna Lina Rahlf; Evi Petersen; Dominique Rehwinkel; Astrid Zech; Daniel Hamacher
Journal:  Front Sports Act Living       Date:  2019-09-18

9.  Reliability of hip joint position sense tests using a clinically applicable measurement tool in elderly participants with unilateral hip osteoarthritis.

Authors:  Ravi Shankar Reddy; Jaya Shanker Tedla; Mastour Saeed Alshahrani; Faisal Asiri; Venkata Nagaraj Kakaraparthi; Paul Silvian Samuel; Praveen Kumar Kandakurti
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

10.  Effects of Hip Bracing on Gait Biomechanics, Pain and Function in Subjects With Mild to Moderate Hip Osteoarthritis.

Authors:  Hannah Steingrebe; Bernd J Stetter; Stefan Sell; Thorsten Stein
Journal:  Front Bioeng Biotechnol       Date:  2022-07-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.