Literature DB >> 24979657

Intravoxel incoherent motion MRI of the healthy pancreas: Monoexponential and biexponential apparent diffusion parameters of the normal head, body and tail.

Chao Ma1, Li Liu, Yan-jun Li, Lu-guang Chen, Chun-shu Pan, Yong Zhang, He Wang, Shi-yue Chen, Jian-ping Lu.   

Abstract

BACKGROUND: To investigate the monoexponential and biexponential apparent diffusion parameters in different anatomical regions of the healthy pancreas using intravoxel incoherent motion (IVIM) diffusion weighted imaging (DWI).
METHODS: Fifty-seven healthy volunteers (age, 45.0 ± 10.8 years) were recruited. DWI of the pancreas was performed with 9 b-values (0, 20, 50, 100, 200, 400, 600, 800, and 1000 s/mm(2) , respectively). The ADC was calculated for all b-values using linear regression yielding ADCtotal . The ADCb value of the monoexponential DWI, slow component of diffusion (ADCslow ), incoherent microcirculation (ADCfast ) and perfusion fraction (f) of the biexponential DWI were calculated for the pancreas head, body and tail. Dependency of the parameters on the anatomical regions was analyzed using Friedman test.
RESULTS: All of the mean ADC400 , ADC600 , ADC800 , ADC1000 , ADCtotal and f values differed significantly among the anatomical regions with the lowest values were observed in the tail of pancreas (P < 0.05). The Friedman test results demonstrated a significant decline of the mean ADC values of the monoexponential DWI from b20 to b1000 for the three anatomical regions respectively (P < 0.001).
CONCLUSION: Multi-b-value DWI derived quantitative parameters including ADC400 , ADC600 , ADC800 , ADC1000 , ADCtotal , and f differed significantly among the pancreatic head, body and tail, with the lowest values obtained in the tail.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  IVIM; apparent diffusion coefficient; biexponential apparent diffusion; diffusion weighted imaging; pancreas

Mesh:

Year:  2014        PMID: 24979657     DOI: 10.1002/jmri.24684

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  Intravoxel incoherent motion diffusion-weighted imaging in the characterization of Alzheimer's disease.

Authors:  Nengzhi Xia; Yanxuan Li; Yingnan Xue; Weikang Li; Zhenhua Zhang; Caiyun Wen; Jiance Li; Qiong Ye
Journal:  Brain Imaging Behav       Date:  2021-09-04       Impact factor: 3.978

2.  Intravoxel incoherent motion DWI of the pancreatic adenocarcinomas: monoexponential and biexponential apparent diffusion parameters and histopathological correlations.

Authors:  Chao Ma; Yanjun Li; Li Wang; Yang Wang; Yong Zhang; He Wang; Shiyue Chen; Jianping Lu
Journal:  Cancer Imaging       Date:  2017-04-28       Impact factor: 3.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.