Literature DB >> 24979296

Evaluation of the analytical and clinical performances of time-resolved fluoroimmunoassay for detecting carcinoma antigen 50.

Meijuan Xie1, He Huang, Jianfeng Hang, Zhining Dong, Dengyan Xiao, Ping Xu, Cuiying Zhu, Weiwen Xu.   

Abstract

We developed a TR-FIA kit for quantitative detection of CA50. This study aims to evaluate the analytical and clinical performances of this kit. Precision, accuracy, specificity, sensitivity, stability, and endogenous interference of this kit are evaluated. Reference range is established. Coincidence rate and correlation between TR-FIA and RIA are evaluated. ROC is adopted to evaluate the diagnostic performance. This kit shows excellent precision with a coefficients of variation (CVs) ranged from 2.2-9.3%, accuracy (average recovery, 98.5%), sensitivity (minimum detectable concentration is 0.2 U/mL), specificity (all cross-reactivity is less than 0.1% except CA199, which is 0.175%), and storage stability (recoveries, 90.8-100.4%). Bilirubin, hemoglobin, and triglyceride dose not interfere with CA50 detection (recovery, 97.13-109.1%). The range from 0-25 U/mL is chosen as the reference range. There are good correlation (r = 0.804) and coincidence (p = 0.608, kappa = 0.924) between TR-FIA and RIA. Diagnostic performance of this kits, which based on RIA results, is perfect (AUC = 0.996), and the diagnostic accuracy for malignancy diagnosis is in moderate degree (AUC, 0.802-0.861). The TR-FIA (CA50) kit performs well in analytical and clinical performances, and can be employed in the clinical diagnosis of malignancy.

Entities:  

Keywords:  analytical performance; carcinoma antigen 50; clinical performance; malignancy; time-resolved fluoroimmunoassay; tumor marker

Mesh:

Substances:

Year:  2015        PMID: 24979296     DOI: 10.1080/15321819.2014.937542

Source DB:  PubMed          Journal:  J Immunoassay Immunochem        ISSN: 1532-1819


  3 in total

1.  A Multi-Region Magnetoimpedance-Based Bio-Analytical System for Ultrasensitive Simultaneous Determination of Cardiac Biomarkers Myoglobin and C-Reactive Protein.

Authors:  Zhen Yang; Huanhuan Wang; Pengfei Guo; Yuanyuan Ding; Chong Lei; Yongsong Luo
Journal:  Sensors (Basel)       Date:  2018-06-01       Impact factor: 3.576

2.  Detection of Carbohydrate Antigen 50 Based on a Novel Miniaturized Chemiluminescence Analyzer Enables Large-Scale Cancer Early Screening in Grassroots Community.

Authors:  Yu Liu; Xiaowei He; Jingjing Zou; Xiuyun Ouyang; Chunrong Huang; Xiao Yang; Yu Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-07-07

Review 3.  Translational progress on tumor biomarkers.

Authors:  Hongwei Guo; Xiaolin Zhou; Yi Lu; Liye Xie; Qian Chen; Evan T Keller; Qian Liu; Qinghua Zhou; Jian Zhang
Journal:  Thorac Cancer       Date:  2015-07-27       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.