Literature DB >> 24975757

Component selection in revision total hip arthroplasty.

Antonia F Chen1, William J Hozack2.   

Abstract

Component selection for revision total hip arthroplasty is important for creating a stable hip, providing offset to maximize joint mechanics, and restoring appropriate leg lengths. On the femoral side, fully porous coated stems, modular tapered stems, and proximal femoral replacements can be used depending on the level of bone loss. For the acetabulum, smaller defects can be contained using second-generation porous coating hemispherical cups, whereas larger acetabular defects can be contained with cup cages, cages, or custom triflange implants. In addition, acetabular liners can improve stability through altered cup version, dual mobility, or constraint of the femoral head.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acetabular augments; Cages; Fully porous coated stems; Modular components; Revision total hip arthroplasty; Trabecular metal

Mesh:

Substances:

Year:  2014        PMID: 24975757     DOI: 10.1016/j.ocl.2014.03.001

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  5 in total

1.  The biological acetabular reconstruction with bone allografts in hip revision arthroplasty.

Authors:  L Busanelli; F Castagnini; B Bordini; S Stea; P P Calderoni; A Toni
Journal:  Musculoskelet Surg       Date:  2018-10-16

2.  The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

Authors:  Yuanqing Mao; Chen Xu; Jiawei Xu; Huiwu Li; Fengxiang Liu; Degang Yu; Zhenan Zhu
Journal:  Int Orthop       Date:  2015-08-19       Impact factor: 3.075

3.  Salvage of Failed Femoral Neck Fracture Fixation with Conversion Total Hip Arthroplasty Using the Direct Anterior Approach.

Authors:  Andrew Yun; Marilena Qutami; Kory B Dylan Pasko
Journal:  Hip Pelvis       Date:  2020-12-03

4.  A novel revision system for complex pelvic defects utilizing 3D-printed custom prosthesis.

Authors:  Yongqiang Hao; Dinghao Luo; Junxiang Wu; Lei Wang; Kai Xie; Mengning Yan; Kerong Dai; Yongqiang Hao
Journal:  J Orthop Translat       Date:  2021-12-15       Impact factor: 5.191

5.  Two-stage Revision for Salmonella-infected Total Hip Replacement, Complicated by a Periprosthetic Fracture.

Authors:  Mohammad Zeeshan Nasser; Nikhil Sharma; Peter Shewell
Journal:  J Orthop Case Rep       Date:  2020-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.