Literature DB >> 24975118

Finite element analysis of the influence of geometry and design of zirconia crowns on stress distribution.

Lilian Costa Anami1, Julia Magalhaes da Costa Lima, Pedro Henrique Corazza, Eron Toshio Colauto Yamamoto, Marco Antonio Bottino, Alexandre Luiz Souto Borges.   

Abstract

PURPOSE: To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA).
MATERIALS AND METHODS: Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed.
RESULTS: The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models.
CONCLUSIONS: The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown.
© 2014 by the American College of Prosthodontists.

Entities:  

Keywords:  Preparation geometry; bilaminate system; restoration design; zirconia

Mesh:

Substances:

Year:  2014        PMID: 24975118     DOI: 10.1111/jopr.12175

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  Investigating inlay designs of class II cavity with deep margin elevation using finite element method.

Authors:  Yung-Chung Chen; Chi-Lun Lin; Chun-Hsien Hou
Journal:  BMC Oral Health       Date:  2021-05-16       Impact factor: 2.757

2.  The effect of different geometric shapes and angles on the fracture strength of IPS e.max computer-aided designed ceramic onlays: An in vitro study.

Authors:  Jonathan Chu; Vincent Bennani; John M Aarts; Nicholas Chandler; Bronwyn Lowe
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

3.  Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas.

Authors:  Estefanía Aranda Yus; Josep Maria Anglada Cantarell; Antonio Miñarro Alonso
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  3 in total