| Literature DB >> 24973843 |
Vimal Mehta1, Bhagya Narayan Pandit2, Jamal Yusuf2, Saibal Mukhopadhyay2, Jagdeep Yadav2, Vijay Trehan2, Sanjay Tyagi2.
Abstract
Balloon angioplasty of the stenosed aorta is usually a relatively simple, yet potentially a catastrophic procedure. Aortic rupture during aortoplasty, though uncommon, carries a high mortality. We report case of a 39-year-old female with aortoarteritis with multiple arterial stenoses whose infra-renal abdominal aorta ruptured during balloon dilatation of the stent deployed in that segment. The site of aortic rupture was temporarily occluded by low-pressure inflation of the same balloon and then was sealed using a stent-graft introduced by contra-lateral femoral arterial access.Entities:
Keywords: Aortic rupture; Aortoarteritis; Aortoplasty; Takayasu arteritis
Mesh:
Year: 2014 PMID: 24973843 PMCID: PMC4121742 DOI: 10.1016/j.ihj.2014.03.017
Source DB: PubMed Journal: Indian Heart J ISSN: 0019-4832