Abstract

A subset of patients undergoing primary total shoulder arthroplasty (TSA) have a medialized joint line secondary to glenoid wear. In some cases, the central pegs or peripheral pegs of a peg design glenoid component may violate the medial cortex of the glenoid vault. It is unknown whether this leads to early failure. The objectives of this study were to determine (1) whether glenoid components with uncontained pegs would be associated with a high rate of failure and (2) whether peg perforation would be associated with inferior clinical outcomes. The authors performed a case-control retrospective review comparing 25 TSAs in which one or multiple pegs perforated the medial glenoid vault (uncontained group) with 25 TSAs without peg perforation (contained group). Implant survival was calculated with revision for glenoid component loosening as the primary outcome variable. Clinical outcomes were determined using American Shoulder and Elbow Surgeons (ASES) and Penn Shoulder Scores. Average follow-up was more than 5 years. No patient in either group had symptomatic glenoid loosening. Two (8%) patients in the uncontained group required revision for rotator cuff tears. Penn and ASES scores were significantly lower in the uncontained group (Penn, P=.002; ASES, P=.004). Pain and satisfaction subscores were similar between the groups, but function subscores were significantly lower in the uncontained group (Penn, P=.002; ASES, P=.005). Uncontained pegs of an anchor peg glenoid component are not associated with early glenoid loosening. Similar pain relief is obtained when compared with contained glenoid components, but shoulder function is significantly lower in patients with uncontained pegs. Copyright 2014, SLACK Incorporated.

Entities:  

Mesh:

Year:  2014        PMID: 24972442     DOI: 10.3928/01477447-20140528-61

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  13 in total

1.  One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers.

Authors:  Frederick A Matsen; Joseph P Iannotti; R Sean Churchill; Lieven De Wilde; T Bradley Edwards; Matthew C Evans; Edward V Fehringer; Gordon I Groh; James D Kelly; Christopher M Kilian; Giovanni Merolla; Tom R Norris; Giuseppe Porcellini; Edwin E Spencer; Anne Vidil; Michael A Wirth; Stacy M Russ; Moni Neradilek; Jeremy S Somerson
Journal:  Int Orthop       Date:  2018-12-03       Impact factor: 3.075

2.  Risk of Perforation Is High During Corrective Reaming of Retroverted Glenoids: A Computer Simulation Study.

Authors:  Alexander W Aleem; Nathan D Orvets; Brendan C Patterson; Aaron M Chamberlain; Jay D Keener
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

3.  Does Postoperative Glenoid Retroversion Affect the 2-Year Clinical and Radiographic Outcomes for Total Shoulder Arthroplasty?

Authors:  Benjamin C Service; Jason E Hsu; Jeremy S Somerson; Stacy M Russ; Frederick A Matsen
Journal:  Clin Orthop Relat Res       Date:  2017-07-05       Impact factor: 4.176

4.  Tomographic Analysis of Positioning of Reverse Baseplates Positioning.

Authors:  Alexandre Almeida; Daniel C Agostini; Pietro Ft Nesello; Nayvaldo C de Almeida; Rafael Mioso; Ana Paula Agostini
Journal:  J Shoulder Elb Arthroplast       Date:  2021-02-15

5.  Assessing the required glenoid peg penetration in native scapula when bone graft is used during primary and revision shoulder arthroplasty.

Authors:  Daoud Makki; Basel Balbisi; Mohammed S Arshad; Puneet Monga; Steven Bale; Ian Trail; Michael Walton
Journal:  Shoulder Elbow       Date:  2021-01-20

6.  Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve.

Authors:  Gregory I Pace; Rachel A Thomas; Connor L Zale; Gregory S Lewis; Raymond Y Kim; H Mike Kim
Journal:  Shoulder Elbow       Date:  2020-01-13

7.  Reverse total shoulder arthroplasty using helical blade to optimize glenoid fixation and bone preservation: preliminary results in thirty five patients with minimum two year follow-up.

Authors:  Sebastien Zilber; Eleonora Camana; Peter Lapner; Emil Haritinian; Laurent Nove Josserand
Journal:  Int Orthop       Date:  2018-03-26       Impact factor: 3.075

8.  Quantitative assessment and characterization of glenoid bone loss in a spectrum of patients with glenohumeral osteoarthritis.

Authors:  D J Lombardo; J Khan; B Prey; L Zhang; G R Petersen-Fitts; V J Sabesan
Journal:  Musculoskelet Surg       Date:  2016-06-03

9.  Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study.

Authors:  Jia-Wei Kevin Ko; Usman Ali Syed; Jonathan D Barlow; Scott Paxton; Bryan J Loeffler; Ocean Thakar; Grant Jamgochian; Joseph A Abboud; Charles L Getz; Gerald R Williams
Journal:  Arch Bone Jt Surg       Date:  2019-07

10.  Glenoid vault perforation in total shoulder arthroplasty: Do we need computer guidance?

Authors:  Jennifer N Flynn; Malin Wijeratna; Matthew Evans; Steven Lee; David McD Taylor; Gregory A Hoy
Journal:  Shoulder Elbow       Date:  2019-11-20