Literature DB >> 24972406

Outcomes after accommodative bioanalogic intraocular lens implantation.

Ioannis G Pallikaris, Dimitra M Portaliou, George D Kymionis, Sophia I Panagopoulou, George A Kounis.   

Abstract

PURPOSE: To evaluate the outcomes after Wichterle Intraocular Lens-Continuous Focus (Medicem, Kamenné Zehrovice, Czech Republic) accommodative bioanalogic intraocular lens implantation.
METHODS: In this prospective case series, 50 eyes of 25 patients (mean age: 65.3 ± 8.4 years; range: 53 to 83 years) were included. All patients underwent routine cataract surgery and Wichterle Intraocular Lens-Continuous Focus implantation.
RESULTS: Mean follow-up was 11.44 ± 2.46 months (range: 9 to 17 months). Both monocular uncorrected and corrected distance visual acuity statistically and significantly (P < .05) improved from 0.31 ± 0.17 (20/63 Snellen) (range: counting fingers to 0.7) to 0.74 ± 0.19 (20/25 Snellen) (range: 0.2 to 1) and from 0.61 ± 0.19 (20/32 Snellen) (range: 0.2 to 1) to 0.82 ± 0.13 (20/25 Snellen) (range: 0.4 to 1), respectively. Target postoperative refraction was -0.5 diopters (D) and preoperative and 1-year postoperative spherical equivalent refraction were 0.72 ± 2.71 D (range: -7.25 to 2.37 D) and -0.24 ± 0.65 D (range: -1.0 to 1.0 D), respectively. No eyes lost lines of corrected distance visual acuity during the follow-up period, whereas 88% of patients gained one or more lines of corrected distance visual acuity. Uncorrected intermediate and near visual acuity were J2 (Snellen 20/25) or better in 72% of patients. No complications occurred intraoperatively or postoperatively. The evaluation of the mean values of root mean square of third and fourth order higher-order aberrations at 1 year postoperatively revealed a mean negative spherical aberration of -0.18 ± 0.13 μm.
CONCLUSIONS: Wichterle Intraocular Lens-Continuous Focus accommodative bioanalogic IOL implantation provides satisfactory visual acuity for far, intermediate, and near distances and the promising results remain stable throughout the follow-up period. Copyright 2014, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24972406     DOI: 10.3928/1081597X-20140520-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye.

Authors:  Jae Yong Kim; Yunhan Lee; Hun Jae Won; Hyerin Jeong; Jin Hyoung Park; Myoung Joon Kim; Hungwon Tchah
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

2.  Optical aberrations, accommodation, and visual acuity with a bioanalogic continuous focus intraocular lens after cataract surgery.

Authors:  Heidar Siatiri; Mehrdad Mohammadpour; Afsaneh Gholami; Elham Ashrafi; Nassim Siatiri; Reza Mirshahi
Journal:  J Curr Ophthalmol       Date:  2017-07-29

3.  Long-Term Evaluation of Visual Outcomes and Patient Satisfaction after Binocular Implantation of a Bioanalogic Lens.

Authors:  Sylwia Wagner; Grzegorz Wagner; Ewa Mrukwa-Kominek
Journal:  J Ophthalmol       Date:  2021-05-07       Impact factor: 1.909

  3 in total