PURPOSE: Electrocardiogram-gated 4D-CTA is a promising technique allowing new insight into aneurysm pathophysiology and possibly improving risk prediction of cerebral aneurysms. Due to the extremely small pulsational excursions (<0.1 mm in diameter), exact segmentation of the aneurysms is of critical importance. In vitro examinations have shown improvement of the accuracy of vessel delineation by iterative reconstruction methods. We hypothesized that this improvement shows a measurable effect on aneurysm pulsations in vivo.
MATERIALS AND METHODS: Ten patients with cerebral aneurysms underwent 4D-CTA. Images were reconstructed with filtered back-projection and iterative reconstruction. The following parameters were compared between both groups: image noise, absolute aneurysm volumes, pulsatility, and sharpness of aneurysm edges.
RESULTS: In iterative reconstruction images, noise was significantly reduced (mean, 9.8 ± 4.0 Hounsfield units versus 8.0 ± 2.5 Hounsfield units; P = .04), but the sharpness of aneurysm edges just missed statistical significance (mean, 3.50 ± 0.49 mm versus 3.42 ± 0.49 mm; P = .06). Absolute volumes (mean, 456.1 ± 775.2 mm(3) versus 461.7 ± 789.9 mm(3); P = .31) and pulsatility (mean, 1.099 ± 0.088 mm(3) versus 1.095 ± 0.082 mm(3); P = .62) did not show a significant difference between iterative reconstruction and filtered back-projection images.
CONCLUSIONS: CT images reconstructed with iterative reconstruction methods show a tendency toward shorter vessel edges but do not affect absolute aneurysm volumes or pulsatility measurements in vivo.
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2014        PMID: 24970550      PMCID: PMC7965181          DOI: 10.3174/ajnr.A4000

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

1.  Novel dynamic four-dimensional CT angiography revealing 2-type motions of cerebral arteries.

Authors:  Yasuyuki Umeda; Fujimaro Ishida; Kazuhide Hamada; Keiji Fukazawa; Yoichi Miura; Naoki Toma; Hidenori Suzuki; Satoshi Matsushima; Shinichi Shimosaka; Waro Taki
Journal:  Stroke       Date:  2011-01-27       Impact factor: 7.914

2.  AAPM tutorial. CT image detail and noise.

Authors:  P Sprawls
Journal:  Radiographics       Date:  1992-09       Impact factor: 5.333

Review 3.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

4.  Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography.

Authors:  Masato Matsumoto; Tatsuya Sasaki; Kyouichi Suzuki; Jun Sakuma; Yuji Endo; Namio Kodama
Journal:  Neurosurgery       Date:  2006-05       Impact factor: 4.654

5.  Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography.

Authors:  Fujimaro Ishida; Hiroyuki Ogawa; Takeo Simizu; Tadashi Kojima; Waro Taki
Journal:  Neurosurgery       Date:  2005-09       Impact factor: 4.654

6.  Strength, elasticity and viscoelastic properties of cerebral aneurysms.

Authors:  H J Steiger; R Aaslid; S Keller; H J Reulen
Journal:  Heart Vessels       Date:  1989       Impact factor: 2.037

7.  Cardiac cycle-related volume change in unruptured cerebral aneurysms: a detailed volume quantification study using 4-dimensional CT angiography.

Authors:  Junko Kuroda; Manabu Kinoshita; Hisashi Tanaka; Takeo Nishida; Hajime Nakamura; Yoshiyuki Watanabe; Noriyuki Tomiyama; Toshiyuki Fujinaka; Toshiki Yoshimine
Journal:  Stroke       Date:  2011-10-13       Impact factor: 7.914

8.  Prediction of impending rupture in aneurysms using 4D-CTA: histopathological verification of a real-time minimally invasive tool in unruptured aneurysms.

Authors:  Y Kato; M Hayakawa; H Sano; M V Sunil; S Imizu; M Yoneda; S Watanabe; M Abe; T Kanno
Journal:  Minim Invasive Neurosurg       Date:  2004-06

9.  Imaging of the walls of saccular cerebral aneurysms with double inversion recovery black-blood sequence.

Authors:  Ji Kang Park; Chang Sub Lee; Ki Bum Sim; Ji Soon Huh; Jung Cheol Park
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

10.  Pulsatility imaging of saccular aneurysm model by 64-slice CT with dynamic multiscan technique.

Authors:  Vahid Yaghmai; Mehdi Rohany; Ali Shaibani; Martin Huber; Haytham Soud; Eric J Russell; Matthew T Walker
Journal:  J Vasc Interv Radiol       Date:  2007-06       Impact factor: 3.464

View more
  2 in total

1.  Reduction of misregistration on cerebral four-dimensional computed tomography angiography images using advanced patient motion correction reconstruction.

Authors:  Yuki Kunitomi; Yoshiyuki Watanabe; Atsuko Arisawa; Akio Tsukabe; Hisashi Tanaka; Hiroto Takahashi; Takeo Nishida; Manabu Kinoshita; Hajime Nakamura; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2016-07-05       Impact factor: 2.374

2.  A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations.

Authors:  L B Stam; R Aquarius; G A de Jong; C H Slump; F J A Meijer; H D Boogaarts
Journal:  Sci Rep       Date:  2021-01-26       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.