Literature DB >> 24970288

Evaluation of the maximum isometric tongue force of healthy volunteers.

J Ulrich Sommer1, Richard Birk, Karl Hörmann, Boris A Stuck.   

Abstract

The forces of specific muscle groups have been well described for nearly all parts of the human body. Interestingly, data for the tongue and its forces are rare. In light of ongoing development of systems for managing the tongue (retaining, advancing, suspending or stabilizing), especially in patients with obstructive sleep apnea, knowledge of the maximum tongue force is important for the conceptual design of those systems. The maximum tongue force in a sagittal direction was documented using a custom-built device that included a tongue clamp and a piezoelectric sensor to capture force measurements. Once positioned securely in the device, participants were asked to move the tongue in a posterior sagittal direction, with maximum force, in each of three test positions. Forty-nine healthy volunteers (29 male) were included in the study. Tongue force measurements were collected three times in three different tongue positions. Thirty-three participants had repeated measurements to investigate any potential learning effect. The maximum force of the human tongue in a posterior sagittal direction showed high inter-individual variation and ranged from 3.2 to 52.4 Newton (N; mean 14.1 ± 7.5 N), when measured from a "neutral protrusion or resting" tongue position. The "retracted" and "maximal protrusion" testing positions yielded lower maximum tongue forces. Men (m) showed statistically significantly higher tongue forces than women (w) (m: 16.0 ± 8.4 N, w: 11.0 ± 4.3 N), and there was a positive correlation with BMI and a negative correlation with age. Comparing the first measurement session with the second session (per patient) showed higher mean maximum forces in the second session, but with no statistical significance. The maximum tongue force data showed substantial inter- and intra-individual variability and gender dependency. Some male individuals produced very high forces. These forces should be considered for the future conception and development of tongue management systems and the mechanical stress to which these systems may be exposed.

Entities:  

Mesh:

Year:  2014        PMID: 24970288     DOI: 10.1007/s00405-014-3103-6

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  44 in total

1.  Effectiveness of a tongue-retaining device.

Authors:  Naoki Higurashi; Makoto Kikuchi; Soichiro Miyazaki; Yoshiaki Itasaka
Journal:  Psychiatry Clin Neurosci       Date:  2002-06       Impact factor: 5.188

2.  Tongue measures in individuals with normal and impaired swallowing.

Authors:  Julie A G Stierwalt; Scott R Youmans
Journal:  Am J Speech Lang Pathol       Date:  2007-05       Impact factor: 2.408

3.  The variation in isometric tension with sarcomere length in vertebrate muscle fibres.

Authors:  A M Gordon; A F Huxley; F J Julian
Journal:  J Physiol       Date:  1966-05       Impact factor: 5.182

4.  Role of the tongue base suspension suture with The Repose System bone screw in the multilevel surgical management of obstructive sleep apnea.

Authors:  Frank R Miller; Daniel Watson; David Malis
Journal:  Otolaryngol Head Neck Surg       Date:  2002-04       Impact factor: 3.497

5.  Strength, endurance, and stability of the tongue and hand in Parkinson disease.

Authors:  N P Solomon; D A Robin; E S Luschei
Journal:  J Speech Lang Hear Res       Date:  2000-02       Impact factor: 2.297

6.  A novel tongue implant for tongue advancement for obstructive sleep apnea: feasibility, safety and histology in a canine model.

Authors:  E Hamans; M Shih; C Roue
Journal:  J Musculoskelet Neuronal Interact       Date:  2010-03       Impact factor: 2.041

7.  Tongue protrusion force and fatiguability in male and female subjects.

Authors:  I L Mortimore; P Fiddes; S Stephens; N J Douglas
Journal:  Eur Respir J       Date:  1999-07       Impact factor: 16.671

8.  Differences in tongue strength across age and gender: is there a diminished strength reserve?

Authors:  Scott R Youmans; Gina L Youmans; Julie A G Stierwalt
Journal:  Dysphagia       Date:  2008-08-09       Impact factor: 3.438

9.  Epidemiology of Obstructive Sleep Apnea: a Population-based Perspective.

Authors:  Won Lee; Swamy Nagubadi; Meir H Kryger; Babak Mokhlesi
Journal:  Expert Rev Respir Med       Date:  2008-06-01       Impact factor: 3.772

Review 10.  Hypopharyngeal surgery in obstructive sleep apnea: an evidence-based medicine review.

Authors:  Eric J Kezirian; Andrew N Goldberg
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2006-02
View more
  1 in total

1.  The Mechanical Properties and Biometrical Effect of 3D Preformed Titanium Membrane for Guided Bone Regeneration on Alveolar Bone Defect.

Authors:  So-Hyoun Lee; Jong-Hoon Moon; Chang-Mo Jeong; Eun-Bin Bae; Chung-Eun Park; Gye-Rok Jeon; Jin-Ju Lee; Young-Chan Jeon; Jung-Bo Huh
Journal:  Biomed Res Int       Date:  2017-09-05       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.