Literature DB >> 24969718

[Effect of two methods of subglottic secretion drainage on the incidence of ventilator-associated pneumonia].

Zhaowu Tao1, Su Zhao2, Gang Yang1, Liangchao Wang1, Shan Zhu1.   

Abstract

OBJECTIVE: To observe the effect of two different ways of subglottic secretion drainage on the incidence of ventilator-associated pneumonia.
METHODS: A total of 149 patients receiving mechanical ventilation from October 2007 to February 2010 in our hospital were enrolled in our study. According to the random number table, they were divided into 3 groups: a control group (47), a intermittent drainage group (54), and a continuous drainage group (48). There was no significant difference in APACHE II score before intubation in the patients of the 3 groups. Conventional treatment and care was performed in the control group, while subglottic rinse was performed every 4 h in the intermittent drainage group and continuous aspiration in the continuous drainage group. The incidence and mortality of ventilator-associated pneumonia were compared among groups within 30 days after intubation. The tolerance and complications were observed.
RESULTS: The incidence rate of early onset ventilator-associated pneumonia in the intermittent drainage group (13.0%) and the continuous drainage group (14.6%) was significantly lower than that in the control group (40.4%), and the difference was statistically significant (χ(2) = 9.914, 7.978;P = 0.002,0.005), but there was no difference between the former 2 groups (χ(2) = 0.056; P = 0.812). There was no significant difference in the incidence of late-onset ventilator-associated pneumonia or mortality among groups (P > 0.05). Good tolerance of the 2 methods was observed.
CONCLUSION: Subglottic secretion drainage by both the intermittent and the continuous methods can efficiently prevent early onset ventilator-associated pneumonia.

Entities:  

Mesh:

Year:  2014        PMID: 24969718

Source DB:  PubMed          Journal:  Zhonghua Jie He He Hu Xi Za Zhi        ISSN: 1001-0939


  2 in total

1.  Subglottic secretion suction for preventing ventilator-associated pneumonia: an updated meta-analysis and trial sequential analysis.

Authors:  Zhi Mao; Ling Gao; Guoqi Wang; Chao Liu; Yan Zhao; Wanjie Gu; Hongjun Kang; Feihu Zhou
Journal:  Crit Care       Date:  2016-10-28       Impact factor: 9.097

2.  Rapid-flow expulsion maneuver in subglottic secretion clearance to prevent ventilator-associated pneumonia: a randomized controlled study.

Authors:  Ying Li; Xue Yuan; Bing Sun; Hai-Chao Li; Hui-Wen Chu; Li Wang; Yu Zhao; Xiao Tang; Rui Wang; Xu-Yan Li; Zhao-Hui Tong; Chen Wang
Journal:  Ann Intensive Care       Date:  2021-06-24       Impact factor: 6.925