The rationale for the optimum efficiency of columns packed with new 1.9μm fully porous Titan-C18 particles-a detailed investigation of the intra-particle diffusivity.

Fabrice Gritti1, Georges Guiochon2.   

Abstract

In a previous report, it was reported that columns packed with fully porous 1.9μm Titan-C18 particles provided a minimum reduced plate height as small as 1.7 for the most retained compound (n-octanophenone) under RPLC conditions. These particles are characterized by a relatively narrow size distribution with a relative standard deviation (RSD) of only 10%. A column packed with classical 5μm Symmetry-C18 particles, used as a reference RPLC column, generated a minimum reduced plate height of 2.1 for the same retained compound. This work demonstrates that this was due to an unusually low intra-particle diffusivity across these particles, which leads to a small longitudinal diffusion coefficient along the column. The demonstration is based on the combination of accurate measurements of the height equivalent to a theoretical plate (HETP), inverse size exclusion chromatography (ISEC), peak parking (PP), and minor disturbance method (MDM) experiments. The experimental results show that the reduced eddy dispersion HETP term (A=0.8 for a reduced velocity of 5), the internal particle porosity (ϵp=0.35), and the enrichment of acetonitrile in the pore volume (75% acetonitrile in the bulk, 85% inside the mesoporous volume) are identical on both the Titan-C18 and Symmetry-C18 columns. The difference between the internal structures of these two brands of RPLC-C18 fully porous particles lies in the values of the internal obstruction factor γp, which is 0.42 for the Symmetry-C18 but only 0.26 for the Titan-C18 particles. This is in part related to the diffusion hindrance due to the small average pore size of the Titan-C18 particles, around 59Å versus 77Å for Symmetry-C18 particles. A simple model of constriction along diffusion paths having the shape of a truncated cone suggests that the width of the pore size distribution (RSD of 30% and 20% for Titan-C18 and Symmetry-C18 particles) is mostly responsible for the difference in their obstruction factors.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Column efficiency; Internal obstruction factor; Intra-particle diffusivity; Particle size distribution; Pore size distribution; Titan-C(18) particles

Mesh:

Substances:

Year:  2014        PMID: 24969087     DOI: 10.1016/j.chroma.2014.05.076

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Investigation of stationary phases performance for eicosanoids profiling in RP-HPLC.

Authors:  Kodjo Nouwade; Sana Tfaili; Pierre Chaminade
Journal:  Anal Bioanal Chem       Date:  2021-09-02       Impact factor: 4.142

2.  The Way to Ultrafast, High-Throughput Enantioseparations of Bioactive Compounds in Liquid and Supercritical Fluid Chromatography.

Authors:  Omar H Ismail; Simona Felletti; Chiara De Luca; Luisa Pasti; Nicola Marchetti; Valentina Costa; Francesco Gasparrini; Alberto Cavazzini; Martina Catani
Journal:  Molecules       Date:  2018-10-20       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.