Accuracy and reliability of the i-STAT point-of-care device for the determination of haemoglobin concentration before and after major blood loss.

W L Ng1, T G Short, K N Gunn, G S Fuge, B Slon.   

Abstract

We investigated the accuracy of i-STAT(®) (Abbott Point of Care Inc., Princeton, NJ, USA) haemoglobin (Hb) measurement in surgical patients with an estimated blood loss of ≥25% of total blood volume. Blood tests for i-STAT(®) Hb, laboratory Hb (Sysmex XE-2100(™), Sysmex Corporation, Kobe, Japan) and total plasma proteins were obtained at the start of surgery (T=0) and when an estimated 25% total blood volume loss had occurred (T=1). Thirty-one patients were recruited. The coefficient of variation of the paired i-STAT(®) Hb estimates was 2.8% and 2.9% at T=0 and T=1, respectively. The mean difference between i-STAT(®) and laboratory Hb was -7.6 g/l (standard deviation 6.5) at T=0 and -5.1 g/l (standard deviation 12) at T=1. The mean total plasma protein difference (total plasma protein T=0 minus T=1) was 13.6 g/l (95% confidence interval 10.2 to 17.0). There was poor correlation between total plasma protein and bias in i-STAT(®) measurements. The i-STAT(®) Hb had an acceptable coefficient of variation, but the Hb levels were lower than those estimated by the laboratory. The standard deviation of i-STAT(®) Hb was greater after ≥25% estimated total blood volume loss. Clinicians should not use the i-STAT(®) Hb in isolation for clinical decision-making when considering blood transfusion in a situation of 25% or greater blood loss.

Entities:  

Keywords:  blood loss; haemoglobin; measurement; point-of-care

Mesh:

Substances:

Year:  2014        PMID: 24967765     DOI: 10.1177/0310057X1404200411

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  3 in total

1.  3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia.

Authors:  Kimberly Plevniak; Matthew Campbell; Timothy Myers; Abby Hodges; Mei He
Journal:  Biomicrofluidics       Date:  2016-10-05       Impact factor: 2.800

2.  Blood gases, biochemistry and haematology of Galápagos marine iguanas (Amblyrhynchus cristatus).

Authors:  Gregory A Lewbart; Maximilian Hirschfeld; J Roger Brothers; Juan Pablo Muñoz-Pérez; Judith Denkinger; Luis Vinueza; Juan García; Kenneth J Lohmann
Journal:  Conserv Physiol       Date:  2015-07-24       Impact factor: 3.079

3.  Factors influencing the bias between blood gas analysis versus central laboratory hemoglobin testing. A secondary analysis of a randomized controlled trial.

Authors:  Linda Tanner; Simone Lindau; Markus Velten; Tobias Schlesinger; Maria Wittmann; Peter Kranke; Kira Berg; Florian Piekarski; Christoph Füllenbach; Suma Choorapoikayil; Dirk Hasenclever; Kai Zacharowski; Patrick Meybohm
Journal:  PLoS One       Date:  2020-10-30       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.