Literature DB >> 24967560

Removal of organic matters and nitrogenous pollutants simultaneously from two different wastewaters using biocathode microbial fuel cell.

Surajbhan Sevda1, T R Sreekrishnan.   

Abstract

In this study, a dual chamber MFC was constructed for simultaneous removal of organic matter and nitrogenous pollutants and bioelectricity generation from synthetic and complex industrial wastewaters and it was operated in batch and continuous mode. When the cell potential was stable after 16 days of batch mode operation, the MFC was converted to continuous mode (from batch mode) and operated for 125 days with different organic loading rates (OLR) and ammonia loading rates (ALR) and fixed hydraulic retention time (HRT) of 40 h. The OLR of 1.49 kg COD m(-3) d(-1) and ALR of 0.58 kg NH3(-) m(-3) d(-1), for anodic and cathodic chambers, respectively, gave the best results. The highest value of cell potential on these OLRs was 310 mV with current density of 85.11 mA m(-2), power density of 26.38 mW m(-2) and volumetric power density of 192.20 mW m(-3). During this period, COD reduction was 78-83% in the anodic chamber and the ammonia reduction was 36-38%. After stable operation with synthetic wastewater one case study was performed with complex industrial wastewater. Continuous mode operation was performed at two different OLR and HRT with a constant ALR. A stable power density and volumetric power density of 23.56 mW m(-2) and 112.50 mW m(-3), respectively were achieved after 24 days of continuous operation at an OLR of 0.35 kg COD/m(3) day with an ALR of 0.43 kg NH3(-) m(-3) day(-1) and corresponding HRT of 68 h. A maximum of 89% COD removal and 40% removal of ammonia was obtained after 50 days. A stable voltage of 300 mV was obtained across 1000 Ω resistance. These findings suggest that BMFC can be used for the treatment of industrial wastewater, with carbon removal in anodic chamber and electricity generation.

Entities:  

Keywords:  Bioanode; ammonia; biocathode; biocathode microbial fuel cell; electroactive biofilm; industrial wastewater

Mesh:

Substances:

Year:  2014        PMID: 24967560     DOI: 10.1080/10934529.2014.910064

Source DB:  PubMed          Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng        ISSN: 1093-4529            Impact factor:   2.269


  1 in total

1.  Enhancing the Electricity Generation and Nitrate Removal of Microbial Fuel Cells With a Novel Denitrifying Exoelectrogenic Strain EB-1.

Authors:  Xiaojun Jin; Fei Guo; Zhimei Liu; Yuan Liu; Hong Liu
Journal:  Front Microbiol       Date:  2018-11-09       Impact factor: 5.640

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.