Literature DB >> 24965564

3D reconstruction of a carotid bifurcation from 2D transversal ultrasound images.

Eunseop Yeom1, Kweon-Ho Nam2, Changzhu Jin2, Dong-Guk Paeng3, Sang-Joon Lee4.   

Abstract

Visualizing and analyzing the morphological structure of carotid bifurcations are important for understanding the etiology of carotid atherosclerosis, which is a major cause of stroke and transient ischemic attack. For delineation of vasculatures in the carotid artery, ultrasound examinations have been widely employed because of a noninvasive procedure without ionizing radiation. However, conventional 2D ultrasound imaging has technical limitations in observing the complicated 3D shapes and asymmetric vasodilation of bifurcations. This study aims to propose image-processing techniques for better 3D reconstruction of a carotid bifurcation in a rat by using 2D cross-sectional ultrasound images. A high-resolution ultrasound imaging system with a probe centered at 40MHz was employed to obtain 2D transversal images. The lumen boundaries in each transverse ultrasound image were detected by using three different techniques; an ellipse-fitting, a correlation mapping to visualize the decorrelation of blood flow, and the ellipse-fitting on the correlation map. When the results are compared, the third technique provides relatively good boundary extraction. The incomplete boundaries of arterial lumen caused by acoustic artifacts are somewhat resolved by adopting the correlation mapping and the distortion in the boundary detection near the bifurcation apex was largely reduced by using the ellipse-fitting technique. The 3D lumen geometry of a carotid artery was obtained by volumetric rendering of several 2D slices. For the 3D vasodilatation of the carotid bifurcation, lumen geometries at the contraction and expansion states were simultaneously depicted at various view angles. The present 3D reconstruction methods would be useful for efficient extraction and construction of the 3D lumen geometries of carotid bifurcations from 2D ultrasound images.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carotid artery; High-frequency ultrasound; Ultrasound imaging; Volume rendering

Mesh:

Year:  2014        PMID: 24965564     DOI: 10.1016/j.ultras.2014.06.002

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  7 in total

1.  Microfluidic measurement for blood flow and platelet adhesion around a stenotic channel: Effects of tile size on the detection of platelet adhesion in a correlation map.

Authors:  Sung Yong Jung; Eunseop Yeom
Journal:  Biomicrofluidics       Date:  2017-04-25       Impact factor: 2.800

2.  Asymmetric pulsation of rat carotid artery bifurcation in three-dimension observed by ultrasound imaging.

Authors:  Changzhu Jin; Kweon-Ho Nam; Dong-Guk Paeng
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-04       Impact factor: 2.357

Review 3.  Imaging of small animal peripheral artery disease models: recent advancements and translational potential.

Authors:  Jenny B Lin; Evan H Phillips; Ti'Air E Riggins; Gurneet S Sangha; Sreyashi Chakraborty; Janice Y Lee; Roy J Lycke; Clarissa L Hernandez; Arvin H Soepriatna; Bradford R H Thorne; Alexa A Yrineo; Craig J Goergen
Journal:  Int J Mol Sci       Date:  2015-05-18       Impact factor: 5.923

4.  Effect of diabetic duration on hemorheological properties and platelet aggregation in streptozotocin-induced diabetic rats.

Authors:  Eunseop Yeom; Hyeokjun Byeon; Sang Joon Lee
Journal:  Sci Rep       Date:  2016-02-22       Impact factor: 4.379

5.  Microfluidics for simultaneous quantification of platelet adhesion and blood viscosity.

Authors:  Eunseop Yeom; Jun Hong Park; Yang Jun Kang; Sang Joon Lee
Journal:  Sci Rep       Date:  2016-04-27       Impact factor: 4.379

6.  Association of Early Atherosclerosis with Vascular Wall Shear Stress in Hypercholesterolemic Zebrafish.

Authors:  Sang Joon Lee; Woorak Choi; Eunseok Seo; Eunseop Yeom
Journal:  PLoS One       Date:  2015-11-12       Impact factor: 3.240

7.  Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.

Authors:  Joerik de Ruijter; Marc van Sambeek; Frans van de Vosse; Richard Lopata
Journal:  Med Phys       Date:  2020-01-03       Impact factor: 4.071

  7 in total