Literature DB >> 24964872

Assessment of skin dose modification caused by application of immobilizing cast in head and neck radiotherapy.

Shokouhozaman Soleymanifard1, Mohammad Taghi Bahreyni Toossi, Mohsen Khosroabadi, Atefeh Vejdani Noghreiyan, Soodabeh Shahidsales, Fatemeh Varshoee Tabrizi.   

Abstract

Skin dose assessment for radiotherapy patients is important to ensure that the dose received by skin is not excessive and does not cause skin reactions. Immobilizing casts may have a buildup effect, and can enhance the skin dose. This study has quantified changes to the surface dose as a result of head and neck immobilizing casts. Medtech and Renfu casts were stretched on the head of an Alderson Rando-Phantom. Irradiation was performed using 6 and 15 MV X-rays, and surface dose was measured by thermoluminescence dosimeters. In the case of 15MV photons, immobilizing casts had no effect on the surface dose. However, the mean surface dose increase reached up to 20 % when 6MV X-rays were applied. Radiation incidence angle, thickness, and meshed pattern of the casts affected the quantity of dose enhancement. For vertical beams, the surface dose increase was more than tangential beams, and when doses of the points under different areas of the casts were analysed separately, results showed that only doses of the points under the thick area had been changed. Doses of the points under the thin area and those within the holes were identical to the same points without immobilizing casts. Higher dose which was incurred due to application of immobilizing casts (20 %) would not affect the quality of life and treatment of patients whose head and neck are treated. Therefore, the benefits of head and neck thermoplastic casts are more than their detriments. However, producing thinner casts with larger holes may reduce the dose enhancement effect.

Entities:  

Mesh:

Year:  2014        PMID: 24964872     DOI: 10.1007/s13246-014-0283-8

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  2 in total

1.  Evaluation of dose calculations accuracy of a commercial treatment planning system for the head and neck region in radiotherapy.

Authors:  Mohammad Taghi Bahreyni Toossi; Bagher Farhood; Shokouhozaman Soleymanifard
Journal:  Rep Pract Oncol Radiother       Date:  2017-08-18

2.  In vivo skin dose measurement in breast conformal radiotherapy.

Authors:  Shokouhozaman Soleymanifard; Seyed Amir Aledavood; Atefeh Vejdani Noghreiyan; Mahdi Ghorbani; Farideh Jamali; David Davenport
Journal:  Contemp Oncol (Pozn)       Date:  2016-02-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.