Literature DB >> 24964763

Effect of oxide layer modification of CoCr stent alloys on blood activation and endothelial behavior.

Vincent Milleret1, Algirdas Ziogas, Stefano Buzzi, Roman Heuberger, Arik Zucker, Martin Ehrbar.   

Abstract

CoCr alloys, in particular MP35N and L605, are extensively used in biomedical implants, for example for coronary stents. In practice, these alloys present a moderately hydrophobic surface which leads to significant platelet adhesion and consequently to risk of early thrombosis or in-stent restenosis. Surface modification of biomedical implants is known to alter their biological performances. In this study we focused on the alteration of in vitro biological responses of human cells contacting CoCr surfaces with engineered oxide layers. XPS analysis was performed to determine the composition of the oxide layer of differently treated CoCr while the bulk properties were not modified. An extensive characterization of the surfaces was performed looking at surface roughness, wettability and charge. After static exposure to blood, strongly reduced platelet and increased polymorphonuclear neutrophil adhesion were observed on treated versus untreated surfaces. Comparisons of treated and untreated samples provide evidence for wettability being an important player for platelet adhesion, although multiple factors including surface oxide chemistry and charge might control polymorphonuclear neutrophil adhesion. The differently treated surfaces were shown to be equally suitable for endothelial cell proliferation. We herein present a novel approach to steer biological properties of CoCr alloys. By adjusting their oxide layer composition, substrates were generated which are suitable for endothelial cell growth and at the same time show an altered (reduced) blood contact activation. Such treatments are expected to lead to stents of highly reproducible quality with minimal thrombogenicity and in-stent restenosis, while maintaining rapid re-endothelialization after coronary angioplasty.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  endothelialization; hemocompatibility; oxide layer; stent; surface modification

Mesh:

Substances:

Year:  2014        PMID: 24964763     DOI: 10.1002/jbm.b.33232

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

Review 1.  Development of In Vitro Endothelialised Stents - Review.

Authors:  Jitsuro Tsukada; P Mela; M Jinzaki; H Tsukada; T Schmitz-Rode; F Vogt
Journal:  Stem Cell Rev Rep       Date:  2021-08-17       Impact factor: 5.739

2.  Surface modification and direct plasma amination of L605 CoCr alloys: on the optimization of the oxide layer for application in cardiovascular implants.

Authors:  Sergio Diaz-Rodriguez; Pascale Chevallier; Carlo Paternoster; Vanessa Montaño-Machado; Céline Noël; Laurent Houssiau; Diego Mantovani
Journal:  RSC Adv       Date:  2019-01-17       Impact factor: 3.361

3.  A Biocompatibility Study of Plasma Nanocoatings onto Cobalt Chromium L605 Alloy for Cardiovascular Stent Applications.

Authors:  Thithuha Phan; John E Jones; Meng Chen; Doug K Bowles; William P Fay; Qingsong Yu
Journal:  Materials (Basel)       Date:  2022-08-29       Impact factor: 3.748

  3 in total