Literature DB >> 24962141

Fast and accurate exhaled breath ammonia measurement.

Steven F Solga1, Matthew L Mudalel2, Lisa A Spacek3, Terence H Risby4.   

Abstract

This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24962141      PMCID: PMC4189414          DOI: 10.3791/51658

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  13 in total

1.  ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  2005-04-15       Impact factor: 21.405

2.  Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity.

Authors:  Tianshu Wang; Andriy Pysanenko; Kseniya Dryahina; Patrik Spaněl; David Smith
Journal:  J Breath Res       Date:  2008-09-08       Impact factor: 3.262

Review 3.  Breath ammonia levels in a normal human population study as determined by photoacoustic laser spectroscopy.

Authors:  T Hibbard; A J Killard
Journal:  J Breath Res       Date:  2011-06-07       Impact factor: 3.262

Review 4.  Determination of ammonia in biological fluids.

Authors:  J R Huizenga; A Tangerman; C H Gips
Journal:  Ann Clin Biochem       Date:  1994-11       Impact factor: 2.057

Review 5.  To pee or not to pee: ammonia hypothesis of hepatic encephalopathy revisited.

Authors:  Liliane Mpabanzi; Steven W M Olde Damink; Marcel C G van de Poll; Peter B Soeters; Rajiv Jalan; Cees H C Dejong
Journal:  Eur J Gastroenterol Hepatol       Date:  2011-06       Impact factor: 2.566

Review 6.  Determination of ammonia concentrations in cirrhosis patients-still confusing after all these years?

Authors:  Claudia Isabel Blanco Vela; Francisco Javier Bosques Padilla
Journal:  Ann Hepatol       Date:  2011-06       Impact factor: 2.400

Review 7.  Hyperammonemia in review: pathophysiology, diagnosis, and treatment.

Authors:  Ari Auron; Patrick D Brophy
Journal:  Pediatr Nephrol       Date:  2011-03-23       Impact factor: 3.714

8.  Ammonia in breath and emitted from skin.

Authors:  F M Schmidt; O Vaittinen; M Metsälä; M Lehto; C Forsblom; P-H Groop; L Halonen
Journal:  J Breath Res       Date:  2013-02-27       Impact factor: 3.262

9.  Clinical investigation of a point-of-care blood ammonia analyzer.

Authors:  Robert Goggs; Sergio Serrano; Balazs Szladovits; Iain Keir; Ryan Ong; Dez Hughes
Journal:  Vet Clin Pathol       Date:  2008-06       Impact factor: 1.180

Review 10.  Ammonium metabolism in humans.

Authors:  Maria M Adeva; Gema Souto; Natalia Blanco; Cristóbal Donapetry
Journal:  Metabolism       Date:  2012-08-24       Impact factor: 8.694

View more
  4 in total

1.  Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults.

Authors:  Lisa A Spacek; Matthew Mudalel; Frank Tittel; Terence H Risby; Steven F Solga
Journal:  J Breath Res       Date:  2015-12-14       Impact factor: 3.262

2.  A Reduced GO-Graphene Hybrid Gas Sensor for Ultra-Low Concentration Ammonia Detection.

Authors:  Chang Wang; Shaochong Lei; Xin Li; Shixi Guo; Ping Cui; Xianqi Wei; Weihua Liu; Hongzhong Liu
Journal:  Sensors (Basel)       Date:  2018-09-18       Impact factor: 3.576

3.  Repeated Measures of Blood and Breath Ammonia in Response to Control, Moderate and High Protein Dose in Healthy Men.

Authors:  Lisa A Spacek; Arthur Strzepka; Saurabh Saha; Jonathan Kotula; Jeffrey Gelb; Sarah Guilmain; Terence Risby; Steven F Solga
Journal:  Sci Rep       Date:  2018-02-07       Impact factor: 4.379

Review 4.  Applications of Near Infrared Photoacoustic Spectroscopy for Analysis of Human Respiration: A Review.

Authors:  Dan C Dumitras; Mioara Petrus; Ana-Maria Bratu; Cristina Popa
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.