Oxygen causes an increase in the longitudinal relaxation rate of tissues through its T1-shortening effect owing to its paramagnetic properties. Due to such effects, MRI has been used to study oxygen-related signal intensity changes in various body parts including cerebrospinal fluid (CSF) space. Oxygen enhancement of CSF has been mainly studied using MRI sequences with relatively longer time resolution such as FLAIR, and T1 value calculation. In this study, fifteen healthy volunteers were scanned using fast advanced spin echo MRI sequence with and without inversion recovery pulse in order to dynamically track oxygen enhancement of CSF. We also focused on the differences of oxygen enhancement at sulcal and ventricular CSF. Our results revealed that CSF signal after administration of oxygen shows rapid signal increase in both sulcal CSF and ventricular CSF on both sequences, with statistically significant predominant increase in sulcal CSF compared with ventricular CSF. CSF is traditionally thought to mainly form from the choroid plexus in the ventricles and is absorbed at the arachnoid villi, however, it is also believed that cerebral arterioles contribute to the production and absorption of CSF, and controversy remains in terms of the precise mechanism. Our results demonstrated rapid oxygen enhancement in sulcal CSF, which may suggest inhaled oxygen may diffuse into sulcal CSF space rapidly probably due to the abundance of pial arterioles on the brain sulci.
Oxygen causes an increase in the longitudinal relaxation rate of tissues through its T1-shortening effect owing to its paramagnetic properties. Due to such effects, MRI has been used to study oxygen-related signal intensity changes in various body parts including cerebrospinal fluid (CSF) space. Oxygen enhancement of CSF has been mainly studied using MRI sequences with relatively longer time resolution such as FLAIR, and T1 value calculation. In this study, fifteen healthy volunteers were scanned using fast advanced spin echo MRI sequence with and without inversion recovery pulse in order to dynamically track oxygen enhancement of CSF. We also focused on the differences of oxygen enhancement at sulcal and ventricular CSF. Our results revealed that CSF signal after administration of oxygen shows rapid signal increase in both sulcal CSF and ventricular CSF on both sequences, with statistically significant predominant increase in sulcal CSF compared with ventricular CSF. CSF is traditionally thought to mainly form from the choroid plexus in the ventricles and is absorbed at the arachnoid villi, however, it is also believed that cerebral arterioles contribute to the production and absorption of CSF, and controversy remains in terms of the precise mechanism. Our results demonstrated rapid oxygen enhancement in sulcal CSF, which may suggest inhaled oxygen may diffuse into sulcal CSF space rapidly probably due to the abundance of pial arterioles on the brain sulci.
Oxygen causes an increase in the longitudinal relaxation rate of tissues through its T1-shortening effect owing to its paramagnetic properties, no T2-shortening effect of oxygen is seen [1], [2]. Due to such effects, magnetic resonance imaging (MRI) has been used to study oxygen-related signal intensity (SI) changes in various body organs, such as the lungs [3], brain [4], spleen, myocardium, subcutaneous fat, kidneys, bone marrow, liver and arterial blood [2], [5], [6]. The paramagnetic effect of deoxyhemoglobin has frequently been used in the brain to visualize blood-oxygen-level-dependent (BOLD) contrast as functional MRI [7], [8], and the paramagnetic effect of the oxygen molecule itself has also been used to quantify the oxygen content of cerebrospinal fluid (CSF), and to visualize oxygen enhancement (OE) of CSF on MRI [9], [10]. Fluid attenuated inversion recovery (FLAIR) imaging has been mainly used to visualize OE of CSF, since oxygen administration causes signal hyperintensity in CSF of the subarachnoid space on FLAIR [11], [12].CSF acts as a physical cushion for the brain, and plays an important role in its biological waste disposal. This fluid is known to be produced from the choroid plexus in the ventricles, transfers to the cisterns and is eventually absorbed by the arachnoid villi, after exchanging contents with the interstitial fluid of the brain. CSF has been widely visualized using MRI techniques such as MR cisternography [13], [14], phase-contrast MRI [15], [16] and MRI with inversion pulse technique [17], which have provided clues to various pathological processes occurring in the brain. Changes in the oxygen content of CSF are reportedly associated with injury to brain tissue [18], but the resting state of oxygen content and dynamic changes in oxygen content after oxygen inhalation remain unclear. Knowledge of oxygen changes in CSF is also important from the perspective of partial volume effects during imaging analysis, since most cerebral cortices and vessels are surrounded by CSF.OE on MR (OEMR) imaging of CSF has mostly been studied using FLAIR [1], [11], [19], T1 value calculation with inversion recovery (IR)-sequences [2], [10], and dynamic tracking has been performed with relatively longer time resolution [10], [11]. Shorter imaging time without IR will lead to better temporal resolution, but sequences without IR have not been utilized. Fast advanced spin echo (FASE) is a similar sequence with half-Fourier acquisition single-shot turbo spin-echo (HASTE), which has been previously used to calculate T1 values with IR (IR-HASTE) [2], [20]. This study compared FASE to FASE with IR (IR-FASE) in terms of the ability to dynamically track OE of CSF. We also compared OE of sulcal CSF (CSFs) with that of ventricular CSF (CSFv) in each image.
Materials and Methods
Subjects
The approval of the ethics committee of Kyoto University (approval number: C491) and written informed consent were obtained. Fifteen healthy volunteers (12 men, 3 women; mean age, 32±6 years) were recruited, and written informed consent was obtained from all volunteers prior to enrolment.
MRI parameters
IR-FASE and FASE images were acquired using a 3-T MRI scanner (Toshiba Medical Systems, Otawara, Japan) using a 13-channel head coil and the following parameters in a single-slice axial acquisition at the level of 15 mm superior to the anterior commissure – posterior commissure line. IR-FASE: repetition time (TR), 9575 ms; echo time (TE), 48 ms; inversion time (TI), 1915 ms; matrix, 192×192, 1.37×1.37 mm; slice thickness, 7 mm; field of view (FOV), 263×263 mm; flip angle, 90°; bandwidth, 977 Hz/pixel; Number of averaging is two with additional one TR for echo stabilization. FASE: TR, 4500 ms; TE, 48 ms; matrix, 192×192, 1.37×1.37 mm; slice thickness, 7 mm; FOV, 263×263 mm; flip angle, 90°; bandwidth, 977 Hz/pixel; Number of averaging is two with additional one TR for echo stabilization.
Dynamic OEMR
Using IR-FASE (28.8 s/image, 38 measurements) and FASE (13.5 s/image, 80 measurements) to track OE of CSF, images were divided into three phases: 1) pre-oxygen administration (Pre-O2), where subjects breathed normal room air (21% O2) for 5 min; 2) 100% oxygen administration, where subjects breathed 100% O2 at a flow rate of 15 L/min for 5 min; and 3) post-oxygen administration (Post-O2), where subjects breathed normal room air (21% O2) for 8 min. Oxygen was delivered through a non-rebreather mask that was firmly attached to cover the mouth and nose of the subject.
Image analysis
Images from each subject were segmented into CSF and non-CSF components using a trainable segmentation plugin of Fiji [21]. The segmented image was further processed as follows: a CSFs mask image and a CSFv mask image were created. CSFs and CSFv masks were then applied to each image (38 images for IR-FASE, 80 images for FASE) and total SI values for each image were calculated (Fig. 1).
Figure 1
The mean image from FASE is segmented to create CSFs and CSFv masks, which are later applied to each image and total SI values for each image are calculated.
The same process is performed for IR-FASE images. Note that the cavum velum interpositum was not included neirther to CSFv nor CSFs since it belongs to the cistern and it is not located at surfaces.
The mean image from FASE is segmented to create CSFs and CSFv masks, which are later applied to each image and total SI values for each image are calculated.
The same process is performed for IR-FASE images. Note that the cavum velum interpositum was not included neirther to CSFv nor CSFs since it belongs to the cistern and it is not located at surfaces.Normalization was achieved by setting the mean SI of all dynamic images of Pre-O2, O2 and Post-O2 as 1000. Maximum SI (maxSI) of CSF was calculated for each subject from the start of O2 inhalation. Slope of SI (SIslope) was calculated using a differential function for SI curve and maximum SIslope (maxSIslope) of CSF was then calculated for each subject from the start of O2 inhalation. Approximation methods were determined by selecting best R2 value for each approximation: linear curve fitting regression analysis was performed for the Pre-O2 and Post-O2 phases and polynomial curve fitting regression analysis for O2 phase. Mean SI with standard error of CSFs and CSFv signal values in both IR-FASE and FASE independently, and R2 values were calculated for each phase.
Statistical analysis
Paired Student's t-test was conducted to compare maxSI and maxSIslope values for each volunteer in CSFs and CSFv between IR-FASE and FASE, with values of p<0.05 considered statistically significant. MedCalc version 12.2.1 software (MedCalc Software, Mariakerke, Belgium) was used.
Results
IR-FASE images
Pre-O2 showed a linear correlation with time (R2 = 0.06 for CSFs, and R2 = 0.61 for CSFv). With oxygen administration, signal values of CSF increase in correlation with time, with a better polynomial curve fit for CSFs than for CSFv (R2 = 0.97 for CSFs, and R2 = 0.76 for CSFv). Post-O2 signal values decrease with time, showing a linear curve fit (R2 = 0.68 for CSFs, and R2 = 0.02 for CSFv, respectively) (Fig. 2a, c).
Figure 2
IR-FASE for Pre-O2, Post-O2 and O2 phases of OE-MRI of CSFs (a) and CSFv (c), show higher SI with oxygen administration in CSFs compared to CSFv.
FASE for Pre-O2, Post-O2 and O2 phases of OE-MRI of CSFs (b) and CSFv (d), showing higher SI with oxygen administration in CSFs compared to CSFv. All data were shown with mean ± standard errors.
IR-FASE for Pre-O2, Post-O2 and O2 phases of OE-MRI of CSFs (a) and CSFv (c), show higher SI with oxygen administration in CSFs compared to CSFv.
FASE for Pre-O2, Post-O2 and O2 phases of OE-MRI of CSFs (b) and CSFv (d), showing higher SI with oxygen administration in CSFs compared to CSFv. All data were shown with mean ± standard errors.
FASE images
Pre-O2 signals showed a linear correlation with time (R2 = 0.88 for CSFs, and R2 = 0.77 for CSFv). With oxygen administration, signal values of CSF rose in correlation with time, with a better polynomial curve fit in CSFs than CSFv (R2 = 0.94 for CSFs, R2 = 0.72 for CSFv). Post-O2 signal values decrease with time, showing a linear curve fit (R2 = 0.94 for CSFs, and R2 = 0.95 for CSFv) (Fig. 2b, d).
Subtraction images
O2 minus Pre-O2 shows a positive SI difference, while Post-O2 minus O2 shows a negative SI difference in both IR-FASE and FASE images (Fig. 3).
Figure 3
IR-FASE image (a), calculated IR-FASE images: “O2 minus Pre-O2” (b), “Post-O2 minus O2” (c).
FASE image (d), calculated FASE images: “O2 minus Pre-O2” (e), “Post-O2 minus O2” (f). Calculated images of “O2 minus Pre-O2” show a positive SI difference (b, e), while calculated images of “Post-O2 minus O2” show a negative SI difference (c, f). Intra-ventricular high signals in “Post-O2 minus O2” images are assumed to come from the highly vascular choroid plexus.
IR-FASE image (a), calculated IR-FASE images: “O2 minus Pre-O2” (b), “Post-O2 minus O2” (c).
FASE image (d), calculated FASE images: “O2 minus Pre-O2” (e), “Post-O2 minus O2” (f). Calculated images of “O2 minus Pre-O2” show a positive SI difference (b, e), while calculated images of “Post-O2 minus O2” show a negative SI difference (c, f). Intra-ventricular high signals in “Post-O2 minus O2” images are assumed to come from the highly vascular choroid plexus.
IR-FASE vs. FASE
CSFs
Values of maxSI and maxSIslope were significantly higher for IR-FASE than for FASE (p = 0.001 and p<0.0001, respectively) (Table 1, Fig. 4a–b).
Table 1
MaxSI and maxSIslope for IR-FASE and FASE.
maxSI
maxSIslope
IR-FASE
FASE
IR-FASE vs. FASE
IR-FASE
FASE
IR-FASE vs. FASE
CSFs
1073.1±52.8
1015.9±8.3
P = 0.001*
1.277±0.639
0.197±0.078
P<0.0001*
CSFv
1028.1±34.3
1008.1±6.5
P = 0.034*
0.463±0.287
0.061±0.06
P = 0.0001*
CSFs vs. CSFv
P = 0.004*
P<0.0001*
P = 0.0003*
P<0.0001*
All data were shown with mean ± standard errors. *Statistical significance (P<0.05).
Figure 4
Box-and-whisker plots of IR-FASE vs. FASE maxSI and maxSIslope of CSFs (a–b) and CSFv (c–d).
CSFs: maxSI and maxSIslope are significantly higher for IR-FASE than for FASE (p = 0.001 and p<0.0001, respectively) (a, b). CSFv: maxSI and maxSIslope are significantly higher for IR-FASE than for FASE (p = 0.034, and p = 0.0001 respectively) (c, d).
Box-and-whisker plots of IR-FASE vs. FASE maxSI and maxSIslope of CSFs (a–b) and CSFv (c–d).
CSFs: maxSI and maxSIslope are significantly higher for IR-FASE than for FASE (p = 0.001 and p<0.0001, respectively) (a, b). CSFv: maxSI and maxSIslope are significantly higher for IR-FASE than for FASE (p = 0.034, and p = 0.0001 respectively) (c, d).All data were shown with mean ± standard errors. *Statistical significance (P<0.05).
CSFv
Values of maxSI and maxSIslope were significantly higher for IR-FASE than for FASE (p = 0.034, and p = 0.0001, respectively) (Table 1, Fig. 4c–d).
CSFs vs. CSFv
CSFs showed significant higher maxSI and maxSIslope than CSFv in both IR-FASE (p = 0.004 and p = 0.0003 for maxSI and maxSIslope, respectively) (Table 1, Fig. 5a–b) and FASE (p<0.0001 and p<0.0001 for maxSI and maxSIslope, respectively) (Table 1, Fig. 5c–d).
Figure 5
Box-and-whisker plots of CSFs vs. CSFv.
Values of maxSI and maxSIslope are significantly higher for CSFs than for CSFv in both IR-FASE (maxSI, p = 0.004; maxSIslope, p = 0.0003) (a, c) and in FASE (maxSI, p<0.0001; maxSIslope, p<0.0001) (b, d).
Box-and-whisker plots of CSFs vs. CSFv.
Values of maxSI and maxSIslope are significantly higher for CSFs than for CSFv in both IR-FASE (maxSI, p = 0.004; maxSIslope, p = 0.0003) (a, c) and in FASE (maxSI, p<0.0001; maxSIslope, p<0.0001) (b, d).
Discussion
This study demonstrated dynamic tracking OE of CSF on both IR-FASE and FASE, since both methods showed positive signal increases during O2 administration and maxSI data supported these findings. Rapid OE after O2 administration displayed by SIslope was also demonstrated and represented by maxSIslope. In addition, OE of CSFs was visualized better than OE of CSFv on both IR-FASE and FASE. OE differences between CSFs and CSFv appeared largely compatible with previous studies of FLAIR with 5-min imaging sequence [1] and T1 value calculation with 7-min imaging sequence [10], particularly in terms of the regional differences of T1 in CSF spaces such as basilar cisterns, lateral ventricles and cortical sulci. IR-FASE showed more OE of CSFs than FASE. Our results support previous reports of differences between OE of CSFs and OE of CSFv, but with higher temporal resolution than previously described [1], [10].CSF is traditionally thought to mainly form from the choroid plexus in the ventricles and is absorbed at the arachnoid villi [18], [22]. While it is also believed that cerebral arterioles contribute to the production and absorption of CSF [23], controversy remains in terms of the precise mechanisms [24]. Capillaries in direct contact with the CSF form the blood-CSF barrier, where many constituents pass from the intra-arterial environment into CSF [25]–[27]. Since a linear relationship exists between arterial partial oxygen pressure (PaO2) and CSF oxygen tension, increasing PaO2 levels with 100% O2 administration will lead to increased CSF levels of O2. Oxygen diffuses into the CSF through the blood-CSF barrier, and this exchange occurs more in CSFs than in CSFv, due to the abundance of pial vessels on the surface of the brain compared to intra-ventricular vessels. The larger amount of intra-ventricular CSF might also cause more dilution of oxygen. Another cause might be the leaky areas of the blood-brain barrier near the pituitary gland, which would further facilitate oxygen diffusion into CSFs more than into CSFv. All of these mechanisms might contribute to the difference in OE between CSFs and CSFv [1]. A close relationship exists between CSF and arterial flows. Phase-contrast cine MRI has revealed the age-dependence of CSF flow increases and correlations with arterial flow [28]. Our results partly supported the idea that cerebral vessels are engaged in CSF production, since oxygen rapidly transfers to CSF from arteries.IR sequences on MRI have been used to study OE of CSF in most previous reports [1], [11], [12]. Such OE was noticed on FLAIR images of anaesthetized patients and was initially explained by the effects of propofol, which has a similar T1 to CSF that would lead to incomplete nulling of the CSF signal [19]. However, later studies interpreted the hyperintensity as due to the paramagnetic effects of oxygen on CSF, in turn causing T1-shortening effects [11], [12], [29]. Arterial oxygen saturation by hemoglobin is close to 100% in healthy individuals. The partial pressure of dissolved oxygen in the blood represents a small fraction of the total oxygen concentration (less than 0.3%). The concentration of dissolved oxygen in the blood increased after oxygen inhalation and dissolved oxygen in the blood will diffuse into tissues according to the oxygen pressure gradient [1]. FLAIR is the sequence with an IR pulse to nullify the signal of CSF, so changes in T1 relaxation time of CSF interfere with suppression of the CSF signal. The T1-shortening effect has been utilized on FLAIR in various situations [30]. As HASTE sequence was used to calculate T1 values with IR [2], IR-FASE provides a similar T1-shortening effect induced by oxygen as FLAIR, so FASE without IR might also show a weak T1-shortening effect. Since FASE shows T2 contrast, a T2-elongation effect cannot be excluded, although previous reports have claimed no apparent change in T2 relaxation time with oxygen administration [2]. The precise mechanisms remain unclear, and this appears to be the first study to dynamically track OE of CSF on FASE images.OE-MRI might act as a non-invasive method for delineating pathological lesions occupying CSF spaces [31], and to better understand changes in oxygen status in the case of CSF-filled cystic tumors. OE-MRI might have the potential to non-invasively visualize cerebral collateral blood supply in cases of carotid occlusive disease through the diffusion of oxygen into CSF.Several limitations exist, since these methods require a high degree of compliance from the imaged subject; firm fixation of the head was conducted in this study to reduce minor motions of the head. Second, quantification of OE such as T1 value calculation was not conducted in this study. We focused on higher temporal resolution of OE in this study, but rapid T1 calculation imaging is expected in the near future.In conclusion, rapid oxygen enhancement of CSF can be dynamically tracked with both IR-FASE and FASE, and is observed more in CSFs than in CSFv, probably due to the abundance of pial arterioles on the brain surface compared to the intra-ventricular arterial system.
Authors: Greg Zaharchuk; Reed F Busse; Guy Rosenthal; Geoffery T Manley; Orit A Glenn; William P Dillon Journal: Acad Radiol Date: 2006-08 Impact factor: 3.173
Authors: Greg Zaharchuk; Alastair J Martin; Guy Rosenthal; Geoffery T Manley; William P Dillon Journal: Magn Reson Med Date: 2005-07 Impact factor: 4.668
Authors: Núria Bargalló; Lourdes Olondo; Ana I Garcia; Sebastian Capurro; Luis Caral; Jordi Rumia Journal: AJNR Am J Neuroradiol Date: 2005 Nov-Dec Impact factor: 3.825
Authors: Alex A Bhogal; Jeroen Cw Siero; Jaco Zwanenburg; Peter R Luijten; Marielle Ep Philippens; Hans Hoogduin Journal: J Cereb Blood Flow Metab Date: 2016-01-01 Impact factor: 6.200
Authors: Leonie Petitclerc; Lydiane Hirschler; Jack A Wells; David L Thomas; Marianne A A van Walderveen; Mark A van Buchem; Matthias J P van Osch Journal: Neuroimage Date: 2021-11-24 Impact factor: 7.400