Literature DB >> 24955842

Diagnostic accuracy and interobserver agreement of Quasistatic Ultrasound Elastography in the diagnosis of thyroid nodules.

V Cantisani1, P Lodise1, G Di Rocco2, H Grazhdani1, D Giannotti2, G Patrizi2, E Medvedyeva1, M Olive1, C Fioravanti1, L Giacomelli2, C Chiesa2, A Redler2, C Catalano1, F D'Ambrosio1, P Ricci1.   

Abstract

PURPOSE: To assess the best technique and the diagnostic accuracy of Quasistatic Ultrasound Elastography (QUE) in thyroid nodules. Interobserver agreement was also evaluated.
MATERIALS AND METHODS: A preliminary study of 50 patients with 54 thyroid nodules was performed with quantitative software in order to define the best cut-off value of different imaging methods. All patients underwent total thyroidectomy and histopathology findings served as the standard of reference. Thereafter, 154 nodules in 137 consecutive patients were prospectively evaluated by three operators. Findings at fine-needle aspiration cytology and histopathology (N = 60) served as the standard of reference.
RESULTS: The most accurate technique was the axial peri-intranodular measurement method which achieved an area under the ROC curve of 0.961 (95 %CI 0.848 - 1.00) and had an optimal cut-off value of 3.00. QUE in the differentiation of thyroid nodules showed for operator 1: sensitivity 90 % (95 %CI 73.5 - 97.9 %), specificity 92.7 % (95 %CI 86.7 - 96.6 %), LR+ 12.40 (6.54 - 23.50), LR- 0.11 (0.04 - 0.32) and accuracy 91.4 % (95 %CI 85.4 - 97.3 %); for operator 2: sensitivity 86.7 % (95 %CI 69.3 - 96.2 %), specificity 87.1 % (95 %CI 79.9 - 92.4 %), LR+ 6.72 (4.16 - 10.80), LR- 0.15 (0.06 - 0.38) and accuracy 86.9 % (95 %CI 80.0 - 93.7 %); for operator 3: sensitivity 80 % (95 %CI 61.4 - 92.3 %), specificity 83.9 % (95 %CI 76.2 - 89.9 %), LR+ 4.96 (3.20 - 7.70), LR- 0.24 (0.12 - 0.49) and accuracy 81.9 % (95 %CI 74.0 - 89.9 %). Interobserver agreement values between operator 1 and operator 2 (k = 0.79) (p < 0.05, 95 %CI 0.684 - 0.904), between operator 1 and operator 3 (k = 0.73, 95 %CI: 0.607 - 0.854) and between operator 2 and operator 3 (k = 0.71, 95 %CI: 0.584 - 0.835) were significant.
CONCLUSION: QUE provides accurate quantitative evaluation of thyroid nodules with low interobserver variability. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2014        PMID: 24955842     DOI: 10.1055/s-0034-1366467

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  7 in total

1.  Multiparametric ultrasonography and ultrasound elastography in the differentiation of parathyroid lesions from ectopic thyroid lesions or lymphadenopathies.

Authors:  Andrea M Isidori; Vito Cantisani; Elisa Giannetta; Daniele Diacinti; Emanuele David; Valerio Forte; Daniela Elia; Corrado De Vito; Emilia Sbardella; Daniele Gianfrilli; Francesco Monteleone; Jessica Pepe; Salvatore Minisola; Giorgio Ascenti; Vito D'Andrea; Carlo Catalano; Ferdinando D'Ambrosio
Journal:  Endocrine       Date:  2016-10-05       Impact factor: 3.633

Review 2.  Strain Elastography - How To Do It?

Authors:  Christoph F Dietrich; Richard G Barr; André Farrokh; Manjiri Dighe; Michael Hocke; Christian Jenssen; Yi Dong; Adrian Saftoiu; Roald Flesland Havre
Journal:  Ultrasound Int Open       Date:  2017-12-07

3.  Influence of subjects' characteristics and technical variables on muscle stiffness measured by shear wave elastosonography.

Authors:  Chandra Bortolotto; Luca Lungarotti; Ilaria Fiorina; Michela Zacchino; Ferdinando Draghi; Fabrizio Calliada
Journal:  J Ultrasound       Date:  2017-03-01

Review 4.  Strain US Elastography for the Characterization of Thyroid Nodules: Advantages and Limitation.

Authors:  Vito Cantisani; Hektor Grazhdani; Elena Drakonaki; Vito D'Andrea; Mattia Di Segni; Erton Kaleshi; Fabrizio Calliada; Carlo Catalano; Adriano Redler; Luca Brunese; Francesco Maria Drudi; Angela Fumarola; Giovanni Carbotta; Fabrizio Frattaroli; Nicola Di Leo; Mauro Ciccariello; Marcello Caratozzolo; Ferdinando D'Ambrosio
Journal:  Int J Endocrinol       Date:  2015-04-14       Impact factor: 3.257

5.  Complementary Role of Elastography Using Carotid Artery Pulsation in the Ultrasonographic Assessment of Thyroid Nodules: A Prospective Study.

Authors:  Soo Yeon Hahn; Jung Hee Shin; Eun Young Ko; Jung Min Bae; Ji Soo Choi; Ko Woon Park
Journal:  Korean J Radiol       Date:  2018-08-06       Impact factor: 3.500

6.  Median nerve evaluation by shear wave elastosonography: impact of "bone-proximity" hardening artifacts and inter-observer agreement.

Authors:  Chandra Bortolotto; Elena Turpini; Paolo Felisaz; Daniele Fresilli; Ilaria Fiorina; Maria Vittoria Raciti; Elena Belloni; Olivia Bottinelli; Vito Cantisani; Fabrizio Calliada
Journal:  J Ultrasound       Date:  2017-11-17

7.  TIRADS, SRE and SWE in INDETERMINATE thyroid nodule characterization: Which has better diagnostic performance?

Authors:  Ilaria Celletti; Daniele Fresilli; Corrado De Vito; Marco Bononi; Sara Cardaccio; Alessia Cozzolino; Cosimo Durante; Giorgio Grani; Gianmarco Grimaldi; Andrea M Isidori; Carlo Catalano; Vito Cantisani
Journal:  Radiol Med       Date:  2021-06-15       Impact factor: 3.469

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.