Yuichiro Sakamoto1, Satoshi Inoue2, Takashi Iwamura2, Tomoko Yamashita2, Atsushi Nakashima2, Hiroyuki Koami2, Toru Miike2, Mayuko Yahata2, Hisashi Imahase2, Akiko Goto2, Showgo Narumi2, Miho Ohta2, Chris-Kosuke Yamada2.
Abstract
PURPOSE: It has been reported that the Pulse Contour Cardiac Output (PiCCO) is very useful mainly in the field of intensive care and treatment to grasp the pathophysiological conditions of pulmonary edema because of its capability of obtaining data such as Pulmonary Vascular Permeability Index (PVPI) and Extra Vascular Lung Water (EVLW). Furthermore, a high degree of usability of various markers has been reported for better understanding of the pathological conditions in cases with septicemia.Entities:
Keywords: CRP; Endotoxin Activity Assay (EAA); Pulse Contour Cardiac Output (PiCCO); procalcitonin
Mesh:
Substances:
Year: 2014 PMID: 24954326 PMCID: PMC4075402 DOI: 10.3349/ymj.2014.55.4.975
Source DB: PubMed Journal: Yonsei Med J ISSN: 0513-5796 Impact factor: 2.759
Patient Characteristics
PiCCO, Pulse Contour Cardiac Output; EVLW, Extra Vascular Lung Water; PVPI, Pulmonary Vascular Permeability Index.
Underlying Diseases (n=11)
AAA, abdominal aortic aneurysm.
Fig. 1Relationship between EVLW and inflammatory marker. The EAA values were significantly higher in the EVLW-A at 0.46±0.20 compared to the EVLW-N at 0.21±0.19 (p=0.0064) and no correlations between EVLW and PC or CRP were observed. EAA, Endotoxin Activity Assay; PC, procalcitonin; CRP, C reactive protein; EVLW, Extra Vascular Lung Water.
Fig. 2Relationship between PVPI and inflammatory marker. The PVPI-A tended to have higher PC levels at 18.9±21.8 compared to PVPI-N at 2.4±2.2 (p=0.0676), and no correlations between PVPI level and EAA or CRP were observed. EAA, Endotoxin Activity Assay; PC, procalcitonin; CRP, C reactive protein; PVPI, Pulmonary Vascular Permeability Index.
Fig. 3Relationship between EAA and PiCCO data. The PVPI values were significantly higher in the EAA-A at 3.55±0.48 in comparison with EAA-N at 1.99±0.68 (p=0.0029). There was a tendency that EAA-A has higher PVPI values than EAA-N. EAA, Endotoxin Activity Assay; PiCCO, Pulse Contour Cardiac Output; PVPI, Pulmonary Vascular Permeability Index.
Fig. 4Relationship between PC and PiCCO data. The PC values didn't significantly correlate with either EVLW or PVPI. PC, procalcitonin; PiCCO, Pulse Contour Cardiac Output; PVPI, Pulmonary Vascular Permeability Index; EVLW, Extra Vascular Lung Water.