Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model.

Sabrina Ernst1, Stefan Stübinger1,2, Peter Schüpbach3, Michéle Sidler1, Karina Klein1, Stephen J Ferguson4, Brigitte von Rechenberg1,2.   

Abstract

OBJECTIVES: The aim of this study was to compare two different surfaces of one uniform macro-implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen.
MATERIAL AND METHODS: In six mature sheep, n = 36 implants with a highly crystalline and phosphate-enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid-etched surface (SLA) were placed in the pelvic bone. TiU implants were custom-made to match the SLA implant design. The implant stability and bone-to-implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B-SEM), light microscopy (LM), micro-CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed.
RESULTS: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B-SEM. BIC values (B-SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2- to 4-week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B-SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P ≤ 0.05) than after 2 weeks (B-SEM; LM). Biomechanical data confirmed the histological data.
CONCLUSION: The two surfaces proved comparable osseointegration in this sheep model.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  SEM backscatter; bone‐to‐implant contact; dental implants; osseointegration; removal torque test; resonance frequency; sheep; surface

Mesh:

Substances:

Year:  2014        PMID: 24954017     DOI: 10.1111/clr.12411

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.

Authors:  James Rudolph Collins; Brendha P Ogando; Houlin Hong; Wei Hou; Georgios E Romanos
Journal:  Dent J (Basel)       Date:  2022-06-16

2.  Rapid evaluation of bioactive Ti-based surfaces using an in vitro titration method.

Authors:  Weitian Zhao; David Michalik; Stephen Ferguson; Willy Hofstetter; Jacques Lemaître; Brigitte von Rechenberg; Paul Bowen
Journal:  Nat Commun       Date:  2019-05-02       Impact factor: 14.919

3.  Titanium discs coated with 3,4-dihydroxy-l-phenylalanine promote osteogenic differentiation of human bone mesenchymal stem cells in vitro.

Authors:  Ting Ma; Xi-Yuan Ge; Ke-Yi Hao; Xi Jiang; Yan Zheng; Ye Lin; Yu Zhang
Journal:  RSC Adv       Date:  2019-03-19       Impact factor: 3.361

4.  The osseointegration and stability of dental implants with different surface treatments in animal models: a network meta-analysis.

Authors:  Chun-Ping Hao; Nan-Jue Cao; Yu-He Zhu; Wei Wang
Journal:  Sci Rep       Date:  2021-07-05       Impact factor: 4.379

5.  The Influence of Nanostructured Hydroxyapatite Surface in the Early Stages of Osseointegration: A Multiparameter Animal Study in Low-Density Bone.

Authors:  Suelen Cristina Sartoretto; Jose Calasans-Maia; Rodrigo Resende; Eduardo Câmara; Bruna Ghiraldini; Fabio Jose Barbosa Bezerra; Jose Mauro Granjeiro; Monica Diuana Calasans-Maia
Journal:  Int J Nanomedicine       Date:  2020-11-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.