Literature DB >> 24953937

Robust electrochemical analysis of As(III) integrating with interference tests: a case study in groundwater.

Zhong-Gang Liu1, Xing Chen2, Jin-Huai Liu2, Xing-Jiu Huang3.   

Abstract

In Togtoh region of Inner Mongolia, northern China, groundwater encountered high concentrations As contamination (greater than 50 μg L(-1)) causes an increasing concern. This work demonstrates an electrochemical protocol for robust (efficient and accurate) determination of As(III) in Togtoh water samples using Au microwire electrode without the need of pretreatment or clean-up steps. Considering the complicated conditions of Togtoh water, the efficiency of Au microwire electrode was systematically evaluated by a series of interference tests, stability and reproducibility measurements. No obvious interference on the determination of As(III) was observed. Especially, the influence of humic acid (HA) was intensively investigated. Electrode stability was also observed with long-term measurements (70 days) in Togtoh water solution and under different temperatures (0-35 °C). Excellent reproducibility (RSD:1.28%) was observed from different batches of Au microwire electrodes. The results obtained at Au microwire electrode were comparable to that obtained by inductively coupled plasma atomic emission spectroscopy (ICP-AES), indicating a good accuracy. These evaluations (efficiency, robustness, and accuracy) demonstrated that the Au microwire electrode was able to determine As(III) in application to real environmental samples.
Copyright © 2014. Published by Elsevier B.V.

Entities:  

Keywords:  As(III) detection; Au microwire electrode; Electrochemical stripping; Groundwater

Mesh:

Substances:

Year:  2014        PMID: 24953937     DOI: 10.1016/j.jhazmat.2014.05.094

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  2 in total

1.  Calix[4]arene Derivative-Modified Glassy Carbon Electrode: A New Sensing Platform for Rapid, Simultaneous, and Picomolar Detection of Zn(II), Pb(II), As(III), and Hg(II).

Authors:  Sundus Sultan; Afzal Shah; Burhan Khan; Jan Nisar; Muhammad Raza Shah; Muhammad Naeem Ashiq; Mohammad Salim Akhter; Aamir Hassan Shah
Journal:  ACS Omega       Date:  2019-10-04

2.  Direct Quantification of Cd2+ in the Presence of Cu2+ by a Combination of Anodic Stripping Voltammetry Using a Bi-Film-Modified Glassy Carbon Electrode and an Artificial Neural Network.

Authors:  Guo Zhao; Hui Wang; Gang Liu
Journal:  Sensors (Basel)       Date:  2017-07-03       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.