Literature DB >> 24952626

Electrocatalytic oxidation and voltammetric determination of ciprofloxacin employing poly(alizarin red)/graphene composite film in the presence of ascorbic acid, uric acid and dopamine.

Xin Zhang1, Youli Wei1, Yaping Ding2.   

Abstract

A glassy carbon electrode modified with poly(alizarin red)/electrodeposited graphene (PAR/EGR) composite film was prepared and applied to detect ciprofloxacin (CPFX) in the presence of ascorbic, uric acid and dopamine. The morphology and interface property of PAR/EGR films were examined by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electrocatalytic oxidation of CPFX on AR/EGR was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linearity ranged from 4 × 10(-8) to 1.2 × 10(-4) M with a detection limit (S/N=3) of 0.01 μM. The modified electrode could be applied to the individual determination of CPFX as well as the simultaneous determination of CPFX, ascorbic acid, uric acid and dopamine. This method proved to be a simple, selective and rapid way to determine CPFX in pharmaceutical preparation and biological media.
Copyright © 2014. Published by Elsevier B.V.

Entities:  

Keywords:  Alizarin red; Ciprofloxacin; Potentiostatically electrodeposited graphene; Simultaneously detection

Mesh:

Substances:

Year:  2014        PMID: 24952626     DOI: 10.1016/j.aca.2014.05.020

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Validated electrochemical and chromatographic quantifications of some antibiotic residues in pharmaceutical industrial waste water.

Authors:  Heba K Ibrahim; Mona M Abdel-Moety; Sherif A Abdel-Gawad; Medhat A Al-Ghobashy; Mohamed Abdel Kawy
Journal:  Environ Sci Pollut Res Int       Date:  2017-01-14       Impact factor: 4.223

2.  Fluorometric determination of ciprofloxacin using molecularly imprinted polymer and polystyrene microparticles doped with europium(III)(DBM)3phen.

Authors:  Zhuanying Li; Zhimeng Cui; Yiwei Tang; Xiuying Liu; Xuemei Zhang; Bingxiang Liu; Xianghong Wang; Mohamed Shehata Draz; Xue Gao
Journal:  Mikrochim Acta       Date:  2019-05-07       Impact factor: 5.833

3.  Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide-modified glassy carbon electrode.

Authors:  Lucas Vinícius de Faria; Davi Marques de Farias; Thalles Pedrosa Lisboa; Maria Auxiliadora Costa Matos; Rodrigo Alejandro Abarza Munoz; Renato Camargo Matos
Journal:  Anal Bioanal Chem       Date:  2021-04-22       Impact factor: 4.142

4.  Robotic voltammetry with carbon nanotube-based sensors: a superb blend for convenient high-quality antimicrobial trace analysis.

Authors:  Somjai Theanponkrang; Wipa Suginta; Helge Weingart; Mathias Winterhalter; Albert Schulte
Journal:  Int J Nanomedicine       Date:  2015-01-27

5.  A novel poly (glycine) biosensor towards the detection of indigo carmine: A voltammetric study.

Authors:  Jamballi Gangadharappa Gowda Manjunatha
Journal:  J Food Drug Anal       Date:  2017-05-31       Impact factor: 6.157

  5 in total