Literature DB >> 24951964

Assessment of respiratory flow and efforts using upper-body acceleration.

Parastoo Dehkordi1, Kouhyar Tavakolian, Marcin Marzencki, Marta Kaminska, Bozena Kaminska.   

Abstract

In this paper, an innovative method for estimating the respiratory flow and efforts is proposed and evaluated in various postures and flow rates. Three micro electro-mechanical system accelerometers were mounted on the suprasternal notch, thorax and abdomen of subjects in supine, prone and lateral positions to record the upper airway acceleration and the movements of the chest and abdomen wall. The respiratory flow and efforts were estimated from the recorded acceleration signals by applying machine learning methods. To assess the agreement of the estimated signals with the well-established measurement methods, standard error of measurement (SEM) was calculated and ρ=1-SEM was estimated for every condition. A significant agreement between the estimated and reference signals was found (ρ=0.83, 0.82 and 0.89 for the estimated flow, thorax and abdomen efforts respectively). Additionally, the agreement of the estimated and reference flows was assessed by calculating the ratio of time at the tidal peak inspiration flow to the inspiration time (tPTIF/tI) and the ratio of time at the tidal peak expiration flow to the expiration time (tPTEF/tE). Overall mean and standard deviation of absolute value of differences between tPTIF/tI and tPTEF/tE ratios calculated for every breathing cycle of reference and estimated flow were 0.0035 (0.06) and 0.051 (0.032), respectively. The presented results demonstrate the feasibility of using the upper-body acceleration as a simple solution for long-term monitoring of respiratory features.

Mesh:

Year:  2014        PMID: 24951964     DOI: 10.1007/s11517-014-1168-4

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary results.

Authors:  Cheng-Li Que; Christof Kolmaga; Louis-Gilles Durand; Suzanne M Kelly; Peter T Macklem
Journal:  J Appl Physiol (1985)       Date:  2002-10

2.  Assessment of pulmonary flow using impedance pneumography.

Authors:  Ville-Pekka Seppä; Jari Viik; Jari Hyttinen
Journal:  IEEE Trans Biomed Eng       Date:  2010-06-10       Impact factor: 4.538

3.  A robust method for estimating respiratory flow using tracheal sounds entropy.

Authors:  Azadeh Yadollahi; Zahra M K Moussavi
Journal:  IEEE Trans Biomed Eng       Date:  2006-04       Impact factor: 4.538

4.  Improvement of ballistocardiogram processing by inclusion of respiration information.

Authors:  Kouhyar Tavakolian; Ali Vaseghi; Bozena Kaminska
Journal:  Physiol Meas       Date:  2008-06-18       Impact factor: 2.833

Review 5.  Practice parameters for the indications for polysomnography and related procedures: an update for 2005.

Authors:  Clete A Kushida; Michael R Littner; Timothy Morgenthaler; Cathy A Alessi; Dennis Bailey; Jack Coleman; Leah Friedman; Max Hirshkowitz; Sheldon Kapen; Milton Kramer; Teofilo Lee-Chiong; Daniel L Loube; Judith Owens; Jeffrey P Pancer; Merrill Wise
Journal:  Sleep       Date:  2005-04       Impact factor: 5.849

6.  Validation of respiratory signal derived from suprasternal notch acceleration for sleep apnea detection.

Authors:  Parastoo Kh Dehkordi; Marcin Marzencki; Kouhyar Tavakolian; Marta Kaminska; Bozena Kaminska
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

7.  Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults.

Authors:  Andrew L Chesson; Richard B Berry; Allan Pack
Journal:  Sleep       Date:  2003-11-01       Impact factor: 5.849

8.  An accelerometer-based device for sleep apnea screening.

Authors:  Daniel Sánchez Morillo; Juan Luis Rojas Ojeda; Luis Felipe Crespo Foix; Antonio Léon Jiménez
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-07-28

9.  Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea.

Authors:  Philip de Chazal; Conor Heneghan; Elaine Sheridan; Richard Reilly; Philip Nolan; Mark O'Malley
Journal:  IEEE Trans Biomed Eng       Date:  2003-06       Impact factor: 4.538

10.  Time to peak tidal expiratory flow and the neuromuscular control of expiration.

Authors:  C K van der Ent; C P van der Grinten; N E Meessen; S C Luijendijk; P G Mulder; J M Bogaard
Journal:  Eur Respir J       Date:  1998-09       Impact factor: 16.671

View more
  1 in total

1.  Virtual Spirometry and Activity Monitoring Using Multichannel Electrical Impedance Plethysmographs in Ambulatory Settings.

Authors:  Hassan Aqeel Khan; Amit Gore; Jeffrey Ashe; Shantanu Chakrabartty
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-05-23       Impact factor: 3.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.