A robust, state-of-the-art amperometric microbiosensor for glutamate detection.

Donatella Sirca1, Antonella Vardeu1, Milo Pinna1, Marco Diana2, Paolo Enrico1.   

Abstract

Scientific knowledge of glutamate (GLU) neurobiology is severely hampered by the inadequacy of the available in vivo brain sampling techniques. Due to the crucial role of GLU in central nervous system function and pathology, the development of a reliable sampling device is mandatory. GLU biosensor holds potential to address many of the known issues of in vivo GLU measurement. We report here on the development and test of a labor- and cost-effective microbiosensor, suitable to be applied for measuring brain GLU. A glycerol-based cryopreservation method was also tested. Needle type Pt biosensors were coated with a permselective Nafion-Poly(o-phenylenediamine) layer and cross-linked to l-glutamate oxidase with poly(ethylene glycol) diglycidyl ether. Tested in vitro, the device shows high sensitivity and specificity for GLU, while being poorly influenced by common interfering substances such as ascorbate, dopamine and dihydroxyphenylacetic acid. Further, the cryopreservation procedure kept sensitivity unaltered for 30 days and possibly longer. We conclude that a highly efficient GLU biosensor of minimal dimensions can be consistently and affordably constructed with relative ease. Together with the possibility of cryopreservation this shall foster diffusion and exploitation of GLU biosensors technology.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amperometry; Cryopreservation; Glutamate biosensor; Permselective membrane; Platinum

Mesh:

Substances:

Year:  2014        PMID: 24951923     DOI: 10.1016/j.bios.2014.04.054

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain.

Authors:  Mallikarjunarao Ganesana; Elefterios Trikantzopoulos; Yash Maniar; Scott T Lee; B Jill Venton
Journal:  Biosens Bioelectron       Date:  2019-01-30       Impact factor: 10.618

Review 2.  On the Accuracy of In Vivo Ethanol and Acetaldehyde Monitoring, a Key Tile in the Puzzle of Acetaldehyde as a Neuroactive Agent.

Authors:  Paolo Enrico; Marco Diana
Journal:  Front Behav Neurosci       Date:  2017-05-30       Impact factor: 3.558

3.  Self-Organized Nanostructure Modified Microelectrode for Sensitive Electrochemical Glutamate Detection in Stem Cells-Derived Brain Organoids.

Authors:  Babak Nasr; Rachael Chatterton; Jason Hsien Ming Yong; Pegah Jamshidi; Giovanna Marisa D'Abaco; Andrew Robin Bjorksten; Omid Kavehei; Gursharan Chana; Mirella Dottori; Efstratios Skafidas
Journal:  Biosensors (Basel)       Date:  2018-02-05

4.  Characterization of Biosensors Based on Recombinant Glutamate Oxidase: Comparison of Crosslinking Agents in Terms of Enzyme Loading and Efficiency Parameters.

Authors:  Rochelle Ford; Susan J Quinn; Robert D O'Neill
Journal:  Sensors (Basel)       Date:  2016-09-23       Impact factor: 3.576