Literature DB >> 24951734

All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.

Asgeir Gudnason1, Nils P Hailer1, Annette W-Dahl2, Martin Sundberg2, Otto Robertsson2.   

Abstract

BACKGROUND: Currently, the use of metal-backed tibial components is more common than the use of all-polyethylene components in total knee arthroplasty. However, the available literature indicates that all-polyethylene tibial components are not inferior to the metal-backed design. We hypothesized that there would be no difference in the ten-year survival rate between all-polyethylene and metal-backed tibial components of a specific design in a large nationwide cohort.
METHODS: In the Swedish Knee Arthroplasty Register, we identified 27,733 cruciate-retaining total knee replacements using the press-fit condylar prosthesis with either metal-backed or all-polyethylene tibial components inserted from 1999 to 2011. Unadjusted survival functions were calculated with the end points of revision for any reason, revision due to infection, and revision due to reasons other than infection, and the differences between the groups were investigated with the log-rank test. Cox proportional hazard models were fitted to analyze the influence of various covariates on the adjusted relative risk of revision.
RESULTS: The median duration of follow-up was 4.5 years (range, zero to 12.9 years). Of all total knee replacements, 16,896 (60.9%) were in women and 10,837 (39.1%) were in men. Metal-backed components were used in 16,011 total knee arthroplasties (57.7%) and all-polyethylene in 11,722 total knee arthroplasties (42.3%). With revision for any reason as the end point, the all-polyethylene tibial component had slightly superior, unadjusted ten-year survival compared with the metal-backed component: 97.2% (95% confidence interval [CI], 96.7% to 97.7%) compared with 96.6% (95% CI, 96.2% to 96.9%; p = 0.002). Cox multiple regression analysis adjusting for age group, sex, and patellar resurfacing showed that all-polyethylene components had a reduced risk of revision for any reason (relative risk = 0.75; 95% CI, 0.64 to 0.89) and a reduced risk of revision due to infection (relative risk = 0.63; 95% CI, 0.46 to 0.86). Patellar resurfacing and male sex increased the risk of revision due to infection (relative risk = 2.22 [95% CI, 1.37 to 3.62] and 2.21 [95% CI, 1.66 to 2.94], respectively).
CONCLUSIONS: These all-polyethylene tibial components were at least as good as or superior to metal-backed tibial components with respect to implant survivorship at ten years in cruciate-retaining total knee replacements. We concluded that these less expensive all-polyethylene tibial components can be safely and effectively used in total knee arthroplasty. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24951734     DOI: 10.2106/JBJS.M.00373

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  4 in total

Review 1.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

2.  All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.

Authors:  Fan Tang; Yong Zhou; Wenli Zhang; Li Min; Rui Shi; Yi Luo; Hong Duan; Chongqi Tu
Journal:  J Orthop Surg Res       Date:  2017-04-04       Impact factor: 2.359

Review 3.  Cemented all-poly tibia in resource constrained country, affordable and cost-effective care. Is it applicable at this era? Review article.

Authors:  Vickash Kumar; Obada Hasan; Masood Umer; Naveed Baloch
Journal:  Ann Med Surg (Lond)       Date:  2019-09-27

4.  Late stabilization after initial migration in patients undergoing cemented total knee arthroplasty: a 5-year followup of 2 randomized controlled trials using radiostereometric analysis.

Authors:  Shaho Hasan; Bart L Kaptein; Perla J Marang-van de Mheen; Koen T Van Hamersveld; Rob G H H Nelissen; Sören Toksvig-Larsen
Journal:  Acta Orthop       Date:  2022-01-24       Impact factor: 3.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.