Literature DB >> 24951386

Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner.

Shinyoung An1, Sungtae Kim2, Hyunmin Choi3, Jae-Hoon Lee4, Hong-Seok Moon5.   

Abstract

STATEMENT OF PROBLEM: Digital impression systems have been developed to overcome the disadvantages associated with conventional impression methods.
PURPOSE: The purpose of this study was to compare the marginal fit of zirconia copings designed with the use of an iTero digital scanner with those designed by the conventional impression technique.
MATERIAL AND METHODS: Thirty identical cast, base-metal dies from 1 maxillary central incisor prepared for a ceramic crown restoration were fabricated. For the conventional impression group (CI), base metal dies (n=10) were replicated as stone dies by means of a conventional impression technique with polyvinyl siloxane material. For the iTero with polyurethane group (iP), base metal dies (n=10) were replicated as polyurethane dies with the iTero digital impression system. For the iTero with no dies group (iNo), base metal dies (n=10) were scanned with the iTero digital impression system, but no dies were fabricated. For each group, 10 zirconia copings were fabricated based on the stone dies (CI group), polyurethane dies (iP group), or stereolithography files (iNo group). The marginal gap of each specimen was measured with a light microscope at ×50 magnification. One-way analysis of variance and the Tukey honestly significant difference test were used for statistical analysis (α=.05).
RESULTS: Statistically significant differences were found between the CI group and iP group (P<.05) and between the CI group and iNo group (P<.05).
CONCLUSIONS: The marginal gap between the restoration and definitive cast base metal die was greater in the groups that used the digital impression method than in the group that used the conventional impression method. However, the marginal discrepancies of all of the groups were clinically acceptable.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24951386     DOI: 10.1016/j.prosdent.2013.12.024

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  In Vitro Evaluation of the Effect of Different Luting Cements and Tooth Preparation Angle on the Microleakage of Zirconia Crowns.

Authors:  Behnaz Ebadian; Amirhossein Fathi; Melika Savoj
Journal:  Int J Dent       Date:  2021-08-06

3.  Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form.

Authors:  Ji-Man Park
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

Review 4.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

5.  Marginal Fit of Full Contour Monolithic Zirconia in Different Thicknesses and Layered Zirconia Crowns.

Authors:  Mina Mohaghegh; Maryam Firouzmandi; Elham Ansarifard; Laleh Ramazani
Journal:  J Int Soc Prev Community Dent       Date:  2020-09-28

Review 6.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

7.  Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression.

Authors:  Mahnaz Arshad; Amirmohsen Asgari; Mohamad Javad Kharazifard; Narges Ameri
Journal:  Int J Dent       Date:  2022-01-25

Review 8.  Accuracy of marginal adaptation of posterior fixed dental prosthesis made from digital impression technique: A systematic review.

Authors:  Hanuman Chalapathi Kumar; Tannamala Pavan Kumar; Surapaneni Hemchand; Chinni Suneelkumar; Anirudhan Subha
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

9.  Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas.

Authors:  Estefanía Aranda Yus; Josep Maria Anglada Cantarell; Antonio Miñarro Alonso
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

10.  Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.

Authors:  Hasan Kocaağaoğlu; Haydar Albayrak; Sezgi Cinel Sahin; Ayşegül Güleryüz Gürbulak
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.