Literature DB >> 24951190

Off-site smartphone reading of CT images for patients with inconclusive diagnoses of appendicitis from on-call radiologists.

Nak Jong Seong1, Bohyoung Kim, Sungmin Lee, Hee Sun Park, Hyuk Jung Kim, Hyunsik Woo, Heung-Sik Kang, Kyoung Ho Lee.   

Abstract

OBJECTIVE: The purpose of this study was to simulate a mobile consultation in patients with inconclusive diagnosis of appendicitis made by on-call radiologists, as well as to measure the diagnostic confidence and performance of the mobile consultation.
MATERIALS AND METHODS: Two off-site abdominal radiologists interpreted the CT images from 68 patients (including 29 patients with confirmed appendicitis) on a smart-phone for whom the preliminary CT reports by 25 in-house on-call radiologists were inconclusive. The smartphone readings were compared with the preliminary reports by on-call radiologists and with the original final reports by in-house abdominal radiologists. Heat maps, kappa statistics, Wilcoxon signed-rank tests, and ROC curves were used for data analysis.
RESULTS: The heat maps and kappa statistics showed that the smartphone readings were more similar to the final reports than to the preliminary reports. In diagnosing or ruling out appendicitis, the smartphone readings were more confident than the preliminary reports (p ≤ 0.01) and did not significantly differ in diagnostic confidence from the final reports (p ≥ 0.19). The AUCs of the smartphone readings (0.91 and 0.92) did not differ significantly from those of the preliminary (0.85) or final (0.97) reports (p ≥ 0.09).
CONCLUSION: With the given study sample, the diagnostic performance of the off-site smartphone readings did not differ significantly from that of the in-house preliminary reports. However, the smartphone readings provided higher diagnostic confidence than the preliminary reports.

Entities:  

Keywords:  CT; abdomen; appendicitis; mobile; smartphone

Mesh:

Year:  2014        PMID: 24951190     DOI: 10.2214/AJR.13.11787

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Diffusion-weighted imaging with reverse phase-encoding polarity: the added value to the conventional diffusion-weighted imaging in differentiating acute infarctions from hyperintense brainstem artifacts.

Authors:  Gil-Sun Hong; Choong Wook Lee; Mi-Hyun Kim; Seung Won Jang; Sae Rom Chung; Ga Young Yoon; Jeong Kon Kim
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

2.  A Feasibility Study of Telementoring for Identifying the Appendix Using Smartphone-Based Telesonography.

Authors:  Yoonje Lee; Changsun Kim; Hyuk Joong Choi; Bossng Kang; Jaehoon Oh; Tae Ho Lim
Journal:  J Digit Imaging       Date:  2017-04       Impact factor: 4.056

Review 3.  The Empirical Foundations of Teleradiology and Related Applications: A Review of the Evidence.

Authors:  Rashid L Bashshur; Elizabeth A Krupinski; James H Thrall; Noura Bashshur
Journal:  Telemed J E Health       Date:  2016-09-01       Impact factor: 3.536

4.  Joint approach of diffusion- and perfusion-weighted MRI in intra-axial mass like lesions in clinical practice simulation.

Authors:  Ra Gyoung Yoon; Ho Sung Kim; Gil Sun Hong; Ji Eun Park; Seung Chai Jung; Sang Joon Kim; Jeong Hoon Kim
Journal:  PLoS One       Date:  2018-09-07       Impact factor: 3.240

5.  Evaluation of a smartphone for telepathology: Lessons learned.

Authors:  Paul Fontelo; Fang Liu; Yukako Yagi
Journal:  J Pathol Inform       Date:  2015-06-23

6.  Evaluation of Android Smartphones for Telepathology.

Authors:  Donald Ekong; Fang Liu; G Thomas Brown; Arunima Ghosh; Paul Fontelo
Journal:  J Pathol Inform       Date:  2017-04-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.