Ethnic differences of intraocular pressure and central corneal thickness: the Singapore Epidemiology of Eye Diseases study.

Jacqueline Chua1, Yih Chung Tham2, Jiemin Liao2, Yingfeng Zheng1, Tin Aung2, Tien Yin Wong3, Ching-Yu Cheng4.   

Abstract

PURPOSE: To determine the ethnic differences in the distribution of intraocular pressure (IOP) and central corneal thickness (CCT) in a multi-ethnic Asian population by self-reported ethnicity and genetic ancestry.
DESIGN: Population-based, cross-sectional study. PARTICIPANTS: A total of 10 033 adults (3353 Chinese, 3280 Malays, and 3400 Indians) aged >40 years.
METHODS: Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for risk factor assessment. The IOP readings were obtained by Goldmann applanation tonometry (Haag-Streit, Konig, Switzerland) before pupil dilation. The CCT was measured with ultrasound pachymetry. Genetic ancestry was derived using principal component (PC) analysis. Regression models were used to investigate the association of IOP and CCT with potential risk factors and genetic ancestry. MAIN OUTCOME MEASURES: Intraocular pressure and CCT.
RESULTS: After excluding participants with a history of glaucoma surgery or medication, refractive surgery, corneal edema, or corneal dystrophy, IOP and CCT readings were available for 3251 Chinese, 3232 Malays, and 3317 Indians. The mean IOP readings in the Chinese, Malay, and Indian participants were 14.3±3.1, 15.3±3.7, and 15.8±2.9 mmHg, respectively (P < 0.001). The prevalence of participants with IOP ≥21 mmHg was 2.6% in Chinese, 6.2% in Malays, and 4% in Indians (P < 0.001). In the multivariate regression analysis, the Malay and Indian participants on average had 0.81 and 1.43 mmHg higher IOP levels, respectively, than Chinese (P < 0.001). The mean CCT reading was 552.3±33.4 μm in Chinese, 540.9±33.6 μm in Malays, and 540.4±33.6 μm in Indians (P < 0.001). The percentage of participants with CCT <555 μm was 52.8% in Chinese, 68.5% in Malays, and 66.2% in Indians (P < 0.001). The IOP and CCT levels are significantly correlated with genetic ancestry in our South East Asian population.
CONCLUSIONS: Chinese have the thickest CCT but lowest IOP among the 3 major ethnic groups. In addition, there is a higher proportion of Malays with IOP ≥21 mmHg and CCT <555 μm compared with the Chinese or Indians. This disparity across ethnic groups should be taken into account by future studies investigating IOP and CCT as risk factors or diagnostic tests for glaucoma in Asian populations.
Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24950592     DOI: 10.1016/j.ophtha.2014.04.041

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  31 in total

1.  Association of common SIX6 polymorphisms with peripapillary retinal nerve fiber layer thickness: the Singapore Chinese Eye Study.

Authors:  Ching-Yu Cheng; R Rand Allingham; Tin Aung; Yih-Chung Tham; Michael A Hauser; Eranga N Vithana; Chiea Chuen Khor; Tien Yin Wong
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-23       Impact factor: 4.799

Review 2.  Major review: Molecular genetics of primary open-angle glaucoma.

Authors:  Yutao Liu; R Rand Allingham
Journal:  Exp Eye Res       Date:  2017-05-10       Impact factor: 3.467

3.  South African Eye Study (SAES): ethnic differences in central corneal thickness and intraocular pressure.

Authors:  S O Baboolal; D P Smit
Journal:  Eye (Lond)       Date:  2018-01-12       Impact factor: 3.775

Review 4.  The thick and thin of the central corneal thickness in glaucoma.

Authors:  Graham W Belovay; Ivan Goldberg
Journal:  Eye (Lond)       Date:  2018-02-15       Impact factor: 3.775

5.  Analysis of choroidal thickness in ocular hypertensive patients using enhanced depth imaging optical coherence tomography.

Authors:  Zhongjing Lin; Shouyue Huang; Ping Huang; Lei Guo; Hongjun Bian; Yisheng Zhong
Journal:  Lasers Med Sci       Date:  2017-10-13       Impact factor: 3.161

6.  Ethnic Variations in Central Corneal Thickness in a Rural Population in China: The Yunnan Minority Eye Studies.

Authors:  Chen-Wei Pan; Jun Li; Hua Zhong; Wei Shen; Zhiqiang Niu; Yuansheng Yuan; Qin Chen
Journal:  PLoS One       Date:  2015-08-14       Impact factor: 3.240

7.  Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

Authors:  Colin I Clement; Douglas G A Parker; Ivan Goldberg
Journal:  Open Ophthalmol J       Date:  2016-02-29

8.  Joint Effects of Intraocular Pressure and Myopia on Risk of Primary Open-Angle Glaucoma: The Singapore Epidemiology of Eye Diseases Study.

Authors:  Yih-Chung Tham; Tin Aung; Qiao Fan; Seang-Mei Saw; Rosalynn Grace Siantar; Tien Y Wong; Ching-Yu Cheng
Journal:  Sci Rep       Date:  2016-01-13       Impact factor: 4.379

9.  Assessing the Causality between Blood Pressure and Retinal Vascular Caliber through Mendelian Randomisation.

Authors:  Ling-Jun Li; Jiemin Liao; Carol Yim-Lui Cheung; M Kamran Ikram; Tai E Shyong; Tien-Yin Wong; Ching-Yu Cheng
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

10.  [Pachymetry and intraocular pressure measurement by corneal visualization Scheimpflug technology (Corvis ST): A clinical comparison to the gold standard].

Authors:  J Steinberg; J Mehlan; A Frings; V Druchkiv; G Richard; T Katz; S J Linke
Journal:  Ophthalmologe       Date:  2015-09       Impact factor: 1.059

View more