Erythrocyte deformability responses to intermittent and continuous subhemolytic shear stress.

Michael J Simmonds1, Nazli Atac2, Oguz K Baskurt2, Herbert J Meiselman3, Ozlem Yalcin2.   

Abstract

BACKGROUND: Previous studies have demonstrated that red blood cells (RBC) either lyse or at least experience mechanical damage following prolonged exposure to high shear stress (≥100 Pa). Conversely, prolonged shear stress exposure within the physiological range (5-20 Pa, 300 s) was recently reported to improve RBC deformability. This study investigated the relationships between shear stress and RBC deformability to determine the breakpoint between beneficial vs. detrimental exposure to shear stress (i.e., "subhemolytic threshold"). A second aim of the study was to determine whether the frequency of intermittent application of shear stress influenced the subhemolytic threshold.
METHODS: RBC were exposed to various levels of shear stress (0-100 Pa) in a Couette type shearing system for 300 s. RBC deformability was then immediately measured via ektacytometry. Parallel experiments were conducted at the same shear stresses, except the application time differed while keeping constant the total exposure time: shear stress was applied either for 30 s and repeated 10 times (10×30 s) or applied for 15 s and repeated 20 times (20×15 s).
RESULTS: For a range of donors, the subhemolytic threshold with constant shear stress application was between 30-40 Pa. When physiological shear stress was applied in an intermittent manner, more frequent applications tended to improve (i.e., increase) RBC deformability. However, when supra-physiological shear stress was applied, both continuous and intermittent protocols damaged RBC. Changes of RBC mechanical behavior occurred without increases of hemoglobin in the suspending media, thus attesting to the absence of hemolysis.
CONCLUSION: Shear stress has a biphasic effect on the mechanical properties of RBC, with the duration and rate of exposure appearing to have minimal impact on the subhemolytic threshold when compared with the magnitude of applied shear stress.

Entities:  

Keywords:  Mechanical damage; deformability; exposure time; red blood cell; shear stress

Mesh:

Year:  2014        PMID: 24948378     DOI: 10.3233/BIR-140665

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  14 in total

1.  Production of erythrocyte microparticles in a sub-hemolytic environment.

Authors:  James P Buerck; Dustin K Burke; David W Schmidtke; Trevor A Snyder; Dimitrios V Papavassiliou; Edgar A O'Rear
Journal:  J Artif Organs       Date:  2021-01-09       Impact factor: 1.731

2.  Sublethal Supraphysiological Shear Stress Alters Erythrocyte Dynamics in Subsequent Low-Shear Flows.

Authors:  Antony P McNamee; Tom Fitzpatrick; Geoff D Tansley; Michael J Simmonds
Journal:  Biophys J       Date:  2020-10-30       Impact factor: 4.033

3.  Red blood cell mechanical sensitivity improves in patients with sickle cell disease undergoing chronic transfusion after prolonged, subhemolytic shear exposure.

Authors:  Michael J Simmonds; Silvie Suriany; Derek Ponce; Jon A Detterich
Journal:  Transfusion       Date:  2018-10-16       Impact factor: 3.157

4.  HEMOGLOBIN A1c LEVEL HIGHER THAN 9.05% CAUSES A SIGNIFICANT IMPAIRMENT OF ERYTHROCYTE DEFORMABILITY IN DIABETES MELLITUS.

Authors:  Q Li; L Z Yang
Journal:  Acta Endocrinol (Buchar)       Date:  2018 Jan-Mar       Impact factor: 0.877

5.  Blood storage alters mechanical stress responses of erythrocytes.

Authors:  Elif Ugurel; Zeynep Kucuksumer; Buse Eglenen; Ozlem Yalcin
Journal:  Clin Hemorheol Microcirc       Date:  2017       Impact factor: 2.375

6.  Photoplethysmography for the Assessment of Haemorheology.

Authors:  Haneen Njoum; Panayiotis A Kyriacou
Journal:  Sci Rep       Date:  2017-05-03       Impact factor: 4.379

7.  A Flow Induced Autoimmune Response and Accelerated Senescence of Red Blood Cells in Cardiovascular Devices.

Authors:  James P Buerck; Dustin K Burke; David W Schmidtke; Trevor A Snyder; Dimitrios Papavassiliou; Edgar A O'Rear
Journal:  Sci Rep       Date:  2019-12-19       Impact factor: 4.379

8.  The effects of stenting on hemorheological parameters: An in vitro investigation under various blood flow conditions.

Authors:  K Kapnisis; H Seidner; M Prokopi; D Pasias; C Pitsillides; A Anayiotos; E Kaliviotis
Journal:  Clin Hemorheol Microcirc       Date:  2019       Impact factor: 2.375

Review 9.  The Complex Relationship of Extracorporeal Membrane Oxygenation and Acute Kidney Injury: Causation or Association?

Authors:  Daniel J Kilburn; Kiran Shekar; John F Fraser
Journal:  Biomed Res Int       Date:  2016-02-24       Impact factor: 3.411

10.  Centrifugation-induced release of ATP from red blood cells.

Authors:  Jordan E Mancuso; Anjana Jayaraman; William D Ristenpart
Journal:  PLoS One       Date:  2018-09-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.