Literature DB >> 24948374

Treating orthopedic prosthesis with diamond-like carbon: minimizing debris in Ti6Al4V.

Luciane Y S Oliveira1, Neide K Kuromoto, Carlos J M Siqueira.   

Abstract

Prostheses are subject to various forms of failing mechanisms, including wear from ordinary patient motion. Superficial treatments can improve tribological properties of the contact pair, minimizing wear and increasing prostheses lifetime. One possibility is the diamond-like carbon (DLC) coating, where Carbon is deposited with variable ratio of sp(2)/sp(3) structures, leading to an increase in surface hardness. So in this research Ti6Al4V samples were coated with DLC using sputtering process to evaluate the debris release. The Ti6Al4V and Ti6Al4V plus DLC coating surfaces were analyzed using Raman spectroscopy and instrumented indentation (hardness). The wear behavior was tested using a reciprocating linear tribometer. The wear rate was smaller in the coated samples, producing less debris than the untreated Ti6Al4V alloy. Debris morphology was also evaluated, using scanning electronic microscopy, and it was observed that debris size from the coated samples were bigger than those observed from the uncoated Ti6Al4V alloy, above the size that generally triggers biological response from the host.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24948374     DOI: 10.1007/s10856-014-5252-y

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  5 in total

1.  Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions.

Authors:  A Wang; A Essner; C Stark; J H Dumbleton
Journal:  Biomaterials       Date:  1996-05       Impact factor: 12.479

2.  Isolation and morphological characterisation of UHMWPE wear debris generated in vitro.

Authors:  S Affatato; B Fernandes; A Tucci; L Esposito; A Toni
Journal:  Biomaterials       Date:  2001-09       Impact factor: 12.479

3.  Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints.

Authors:  Jonathan J Elsner; Yoav Mezape; Keren Hakshur; Maoz Shemesh; Eran Linder-Ganz; Avi Shterling; Noam Eliaz
Journal:  Acta Biomater       Date:  2010-07-13       Impact factor: 8.947

Review 4.  Biologic effects of implant debris.

Authors:  Nadim J Hallab; Joshua J Jacobs
Journal:  Bull NYU Hosp Jt Dis       Date:  2009

5.  Patients with osteoarthritis and avascular necrosis have better functional outcomes and those with avascular necrosis worse pain outcomes compared to rheumatoid arthritis after primary hip arthroplasty: a cohort study.

Authors:  Jasvinder A Singh; David G Lewallen
Journal:  BMC Med       Date:  2013-09-24       Impact factor: 8.775

  5 in total
  3 in total

1.  Mechanical tests, wear simulation and wear particle analysis of carbon-based nanomultilayer coatings on Ti6Al4V alloys as hip prostheses.

Authors:  Ji Li; Ketao Wang; Zhongli Li; J P Tu; Gong Jin; Jian Su; Bao Zhai
Journal:  RSC Adv       Date:  2018-02-09       Impact factor: 4.036

2.  Antibacterial efficacy of ultrahigh molecular weight polyethylene with silver containing diamond-like surface layers.

Authors:  Norbert Harrasser; Sebastian Jüssen; Ingo J Banke; Ralf Kmeth; Ruediger von Eisenhart-Rothe; Bernd Stritzker; Hans Gollwitzer; Rainer Burgkart
Journal:  AMB Express       Date:  2015-09-21       Impact factor: 3.298

3.  Antibacterial potency of different deposition methods of silver and copper containing diamond-like carbon coated polyethylene.

Authors:  Norbert Harrasser; Sebastian Jüssen; Andreas Obermeir; Ralf Kmeth; Bernd Stritzker; Hans Gollwitzer; Rainer Burgkart
Journal:  Biomater Res       Date:  2016-07-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.