Non-invasive 13C-glucose breath test using residual gas analyzer-mass spectrometry: a novel tool for screening individuals with pre-diabetes and type 2 diabetes.

Chiranjit Ghosh1, Abhijit Maity, Gourab D Banik, Suman Som, Arpita Chakraborty, Chitra Selvan, Shibendu Ghosh, Barnali Ghosh, Subhankar Chowdhury, Manik Pradhan.   

Abstract

We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24946152     DOI: 10.1088/1752-7155/8/3/036001

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  6 in total

1.  Failure of hyperglycemia and hyperinsulinemia to compensate for impaired metabolic response to an oral glucose load.

Authors:  M Hussain; M Janghorbani; S Schuette; R V Considine; R L Chisholm; K J Mather
Journal:  J Diabetes Complications       Date:  2014-11-24       Impact factor: 2.852

2.  Development of minimally invasive 13C-glucose breath test to examine different exogenous carbohydrate sources in patients with glycogen storage disease type Ia.

Authors:  Abrar Turki; Sylvia Stockler; Sandra Sirrs; Ramona Salvarinova; Gloria Ho; Jennifer Branov; Annie Rosen-Heath; Taryn Bosdet; Rajavel Elango
Journal:  Mol Genet Metab Rep       Date:  2022-05-11

3.  Oxygen-18 isotope of breath CO₂ linking to erythrocytes carbonic anhydrase activity: a biomarker for pre-diabetes and type 2 diabetes.

Authors:  Chiranjit Ghosh; Gourab D Banik; Abhijit Maity; Suman Som; Arpita Chakraborty; Chitra Selvan; Shibendu Ghosh; Subhankar Chowdhury; Manik Pradhan
Journal:  Sci Rep       Date:  2015-01-30       Impact factor: 4.379

4.  Halloysite nanotubes capturing isotope selective atmospheric CO2.

Authors:  Subhra Jana; Sankar Das; Chiranjit Ghosh; Abhijit Maity; Manik Pradhan
Journal:  Sci Rep       Date:  2015-03-04       Impact factor: 4.379

5.  Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests.

Authors:  Naoyuki Kawagoe; Osamu Kano; Sho Kijima; Hideki Tanaka; Masaaki Takayanagi; Yoshihisa Urita
Journal:  PLoS One       Date:  2016-08-02       Impact factor: 3.240

Review 6.  European guideline on indications, performance and clinical impact of 13 C-breath tests in adult and pediatric patients: An EAGEN, ESNM, and ESPGHAN consensus, supported by EPC.

Authors:  Jutta Keller; Heinz F Hammer; Paul R Afolabi; Marc Benninga; Osvaldo Borrelli; Enrique Dominguez-Munoz; Dan Dumitrascu; Oliver Goetze; Stephan L Haas; Bruno Hauser; Daniel Pohl; Silvia Salvatore; Marc Sonyi; Nikhil Thapar; Kristin Verbeke; Mark R Fox
Journal:  United European Gastroenterol J       Date:  2021-06-14       Impact factor: 4.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.