Case of early right ventricular pacing lead perforation and review of the literature.

Gary Nash1, John Mark Williams1, Rajasekhar Nekkanti1, Assad Movahed1.   

Abstract

We report a case of a 77-year-old patient with complete atrioventricular block. She underwent permanent pacemaker implantation complicated by right ventricular lead perforation. This was suspected on transthoracic echocardiogram and confirmed by chest computed tomography. The lead was repositioned in the cardiac electrophysiology lab followed by an uneventful course thereafter.

Entities:  

Keywords:  Lead; Pacemaker; Perforation

Year:  2014        PMID: 24945007      PMCID: PMC4061309          DOI: 10.12998/wjcc.v2.i6.206

Source DB:  PubMed          Journal:  World J Clin Cases        ISSN: 2307-8960            Impact factor:   1.337