Literature DB >> 24943809

Qualitative analysis of seized cocaine samples using desorption electrospray ionization- mass spectrometry (DESI-MS).

Natasha Stojanovska1, Mark Tahtouh2, Tamsin Kelly3, Alison Beavis1, Shanlin Fu1.   

Abstract

Desorption electrospray ionization - mass spectrometry (DESI-MS) is a useful technique for the qualitative analysis of compounds found in seized drug material. In this study, DESI-MS was utilized in the screening analysis of illicit cocaine samples. The technique was also applied to the geographical origin determination of these samples. The limit of detection was determined to be 24.3 µg (or 3.47 µg/mm(2) ) and the analysis time was less than 1 minute per sample. The intra-day and inter-day precision for the detection of cocaine was 11 % and 42 %, respectively; therefore the quantitative data provided by DESI-MS was limited in its use for accurate determination of cocaine concentration in a sample. Using the quadrupole time-of-flight (QTOF) mass spectrometer, the presence of cocaine and impurities detected were confirmed by accurate tandem MS data. The qualitative chemical profiles obtained using DESI-MS were compared to two popular analysis techniques, GC-MS and LC-MS. The effects of a range of adulterants including caffeine, procaine, levamisole, lignocaine, paracetamol, and atropine on the detectability of cocaine were also investigated. It was found that the addition of these adulterants in a cocaine sample did not prevent the detection of the analyte itself (there was slight enhancement in some samples), which was useful in drug detection. The detection of truxillines in the seized samples by DESI-MS aided in the preliminary determination of geographical origin, i.e., Bolivian, Peruvian or Colombian leaf origin. The application of DESI-MS to the qualitative analysis and screening of seized cocaine samples demonstrates the potential and applicability of the technique to the fast chemical profiling of illicit samples.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  DESI-MS; cocaine; desorption electrospray ionization - mass spectrometry; drug intelligence; impurity profiling

Mesh:

Substances:

Year:  2014        PMID: 24943809     DOI: 10.1002/dta.1684

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  4 in total

1.  Acute crack cocaine exposure induces genetic damage in multiple organs of rats.

Authors:  Eduardo Gregolin Moretti; Veronica Quispe Yujra; Samuel Rangel Claudio; Marcelo Jose Dias Silva; Wagner Vilegas; Camilo Dias Seabra Pereira; Flavia de Oliveira; Daniel Araki Ribeiro
Journal:  Environ Sci Pollut Res Int       Date:  2016-01-29       Impact factor: 4.223

2.  Using ambient mass spectrometry and LC-MS/MS for the rapid detection and identification of multiple illicit street drugs.

Authors:  Chien-Hua Chiang; Hei-Hwa Lee; Bai-Hsiun Chen; Yi-Ching Lin; Yu-Ying Chao; Yeou-Lih Huang
Journal:  J Food Drug Anal       Date:  2018-12-04       Impact factor: 6.157

3.  Real-time toxicity prediction of Aconitum stewing system using extractive electrospray ionization mass spectrometry.

Authors:  Zi-Dong Qiu; Jin-Long Chen; Wen Zeng; Ying Ma; Tong Chen; Jin-Fu Tang; Chang-Jiang-Sheng Lai; Lu-Qi Huang
Journal:  Acta Pharm Sin B       Date:  2019-09-11       Impact factor: 11.413

4.  Trace residue identification, characterization, and longitudinal monitoring of the novel synthetic opioid β-U10, from discarded drug paraphernalia.

Authors:  Henry West; John L Fitzgerald; Katherine L Hopkins; Michael G Leeming; Matthew DiRago; Dimitri Gerostamoulos; Nicolas Clark; Paul Dietze; Jonathan M White; James Ziogas; Gavin E Reid
Journal:  Drug Test Anal       Date:  2022-05-23       Impact factor: 3.234

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.