Numerical optimization of open-porous bone scaffold structures to match the elastic properties of human cortical bone.

Jan Wieding1, Andreas Wolf2, Rainer Bader2.   

Abstract

Treatment of large segmental bone defects, especially in load bearing areas, is a complex procedure in orthopedic surgery. The usage of additive manufacturing processes enables the creation of customized bone implants with arbitrary open-porous structure satisfying both the mechanical and the biological requirements for a sufficient bone ingrowth. Aim of the present numerical study was to optimize the geometrical parameters of open-porous titanium scaffolds to match the elastic properties of human cortical bone with respect to an adequate pore size. Three different scaffold designs (cubic, diagonal and pyramidal) were numerically investigated by using an optimization approach. Beam elements were used to create the lattice structures of the scaffolds. The design parameters strut diameter and pore size ranged from 0.2 to 1.5mm and from 0 to 3.0mm, respectively. In a first optimization step, the geometrical parameters were varied under uniaxial compression to obtain a structural modulus of 15GPa (Young׳s modulus of cortical bone) and a pore size of 800µm was aimed to enable cell ingrowth. Furthermore, the mechanical behavior of the optimized structures under bending and torsion was investigated. Results for bending modulus were between 9.0 and 14.5GPa. In contrast, shear modulus was lowest for cubic and pyramidal design of approximately 1GPa. Here, the diagonal design revealed a modulus of nearly 20GPa. In a second step, large-sized bone scaffolds were created and placed in a biomechanical loading situation within a 30mm segmental femoral defect, stabilized with an osteosynthesis plate and loaded with physiological muscle forces. Strut diameter for the 17 sections of each scaffold was optimized independently in order to match the biomechanical stability of intact bone. For each design, highest strut diameter was found at the dorsal/medial site of the defect and smallest strut diameter in the center. In conclusion, we demonstrated the possibility of providing optimized open-porous scaffolds for bone regeneration by considering both mechanical and biological aspects. Furthermore, the results revealed the need of the investigation and comparison of different load scenarios (compression, bending and torsion) as well as complex biomechanical loading for a profound characterization of different scaffold designs. The usage of a numerical optimization process was proven to be a feasible tool to reduce the amount of the required titanium material without influencing the biomechanical performance of the scaffold negatively. By using fully parameterized models, the optimization approach is adaptable to other scaffold designs and bone defect situations.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanical loading; Design variations; Femoral bone; Open-porous scaffolds; Optimization; Pore size; Strut thickness

Mesh:

Year:  2014        PMID: 24942627     DOI: 10.1016/j.jmbbm.2014.05.002

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  27 in total

Review 1.  [The latest study on biomimetic mineralized collagen-based bone materials for pediatric skull regeneration and repair].

Authors:  Bo Li; Shuo Wang; Yonggang Zhao; Xiumei Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-03-15

Review 2.  Recent Advances in Tissue Engineering Strategies for the Treatment of Joint Damage.

Authors:  Makeda K Stephenson; Ashley L Farris; Warren L Grayson
Journal:  Curr Rheumatol Rep       Date:  2017-08       Impact factor: 4.592

3.  3D-printed porous titanium changed femoral head repair growth patterns: osteogenesis and vascularisation in porous titanium.

Authors:  Wei Zhu; Yan Zhao; Qi Ma; Yingjie Wang; Zhihong Wu; Xisheng Weng
Journal:  J Mater Sci Mater Med       Date:  2017-03-01       Impact factor: 3.896

4.  Hot isostatic pressure treatment of 3D printed Ti6Al4V alters surface modifications and cellular response.

Authors:  Michael B Berger; Thomas W Jacobs; Barbara D Boyan; Zvi Schwartz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2019-08-30       Impact factor: 3.368

5.  Design and Validation of Additively Manufactured Metallic Cellular Scaffold Structures for Bone Tissue Engineering.

Authors:  Mohammad O Al-Barqawi; Benjamin Church; Mythili Thevamaran; Dan J Thoma; Adeeb Rahman
Journal:  Materials (Basel)       Date:  2022-05-05       Impact factor: 3.748

Review 6.  A review on computer-aided design and manufacturing of patient-specific maxillofacial implants.

Authors:  Afaque Rafique Memon; Enpeng Wang; Junlei Hu; Jan Egger; Xiaojun Chen
Journal:  Expert Rev Med Devices       Date:  2020-03-12       Impact factor: 3.166

7.  A Mechanobiology-based Algorithm to Optimize the Microstructure Geometry of Bone Tissue Scaffolds.

Authors:  Antonio Boccaccio; Antonio Emmanuele Uva; Michele Fiorentino; Luciano Lamberti; Giuseppe Monno
Journal:  Int J Biol Sci       Date:  2016-01-01       Impact factor: 6.580

8.  The Application of Digital Design Combined with 3D Printing Technology in Skin Flap Transplantation for Fingertip Defects during the COVID-19 Epidemic.

Authors:  Hui Lu; Hanshu Peng; Ze Peng; Dingxi Liu; Qimei Wu; Rong Liu
Journal:  Biomed Res Int       Date:  2021-06-08       Impact factor: 3.411

9.  Geometry Design Optimization of Functionally Graded Scaffolds for Bone Tissue Engineering: A Mechanobiological Approach.

Authors:  Antonio Boccaccio; Antonio Emmanuele Uva; Michele Fiorentino; Giorgio Mori; Giuseppe Monno
Journal:  PLoS One       Date:  2016-01-15       Impact factor: 3.240

10.  Electron beam melting in the fabrication of three-dimensional mesh titanium mandibular prosthesis scaffold.

Authors:  Rongzeng Yan; Danmei Luo; Haitao Huang; Runxin Li; Niu Yu; Changkui Liu; Min Hu; Qiguo Rong
Journal:  Sci Rep       Date:  2018-01-15       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.