The scintigraphic characteristics of ventricular pre-excitation through Mahaim fibers with the use of phase analysis.

N Schechtmann1, E H Botvinick, M Dae, M M Scheinman, J W O'Connell, J Davis, S Winston, A Schwartz, J Abbott.   

Abstract

The phase image pattern of blood pool scintigrams was blindly assessed in 11 patients exhibiting conduction through Mahaim pathways, including 6 nodoventricular and 5 fasciculoventricular. These patterns were compared with the phase image findings in normal subjects, patients with left and right bundle branch block in the absence of pre-excitation and patients with pre-excitation through atrioventricular (AV) connections. In all patients with a Mahaim pathway, the site of earliest phase angle was septal or paraseptal. Phase progression was asymmetric and the pre-excited ventricle demonstrated the earliest mean ventricular phase angle in 10 of 11 patients. This pattern, and the associated ventricular phase difference, appeared to vary from that in normal subjects and in those with a septal AV connection, in whom phase progression is generally symmetric. Scintigraphic phase analysis provided localizing information and presented patterns consistent with Mahaim pathways. Although not able to differentiate among Mahaim pathway subtypes, these phase patterns differed from those in normal subjects, those with right and left lateral free wall pathways and most patients with a septal AV pathway. However, the phase pattern of patients with a Mahaim pathway may not differ from that of patients with a septal AV connection displaying an asymmetric pattern of phase progression, or those with left and right bundle branch block in the absence of pre-excitation. Objective, yet imperfect phase measurements supported these differences. Such image findings may complement the often complex electrophysiologic evaluation of patients presenting with pre-excitation.

Entities:  

Mesh:

Year:  1989        PMID: 2494242     DOI: 10.1016/0735-1097(89)90231-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

Review 1.  Scintigraphic blood pool and phase image analysis: the optimal tool for the evaluation of resynchronization therapy.

Authors:  Elias H Botvinick
Journal:  J Nucl Cardiol       Date:  2003 Jul-Aug       Impact factor: 5.952

2.  Limitations of parametric modeling of the left ventricle using first harmonic analysis: possible role for gaussian modeling.

Authors:  Christopher L Hansen
Journal:  J Nucl Cardiol       Date:  2014-05-09       Impact factor: 5.952

3.  The relationship of myocardial contraction and electrical excitation--the correlation between scintigraphic phase image analysis and electrophysiologic mapping.

Authors:  L Munoz del Romeral; C Stillson; M Lesh; M Dae; Elias Botvinick
Journal:  J Nucl Cardiol       Date:  2009-07-28       Impact factor: 5.952