Abstract
BACKGROUND: Due to students' initial inexperience, slides are frequently broken and blood smears are damaged in microscopy training, leading to the need for their constant replacement. To minimize this problem a method of preparing blood smears on transparent acetate sheets was developed with the goal of implementing appropriate and more readily available teaching resources for the microscopic diagnosis of malaria.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24938886 PMCID: PMC4069278 DOI: 10.1186/1475-2875-13-238
Source DB: PubMed Journal: Malar J ISSN: 1475-2875 Impact factor: 2.979
Figure 1Steps for preparing a thin smear on a transparent acetate sheet.
Figure 2Steps for preparing a thick smear on a transparent acetate sheet.
Figure 3Tray staining of a thin (A) and thick smear (B) on a transparent acetate sheet.
Figure 4Thick (A) and thin (B) blood smears prepared on acetate sheets after staining.
Figure 5Mounting of a smear fragment in acetate upon a glass slide: a drop of immersion oil is added (A) and the acetate fragment is placed on top (B). The slide is mounted with a thin (C) and thick (D) smear fragment.
Figure 6Applying of the finishing varnish over the blood smear prepared on acetate sheet using a syringe (A) and spreading it with a glass rod (B).
Information on the acetate sheets tested for their resistance in contact with methanol
| PVC | Adina | Architectural model makin | Yes | Adina Indústria e Comercio de Fechos, Rio de Janeiro, Brazil |
| PPC | Mares | Laser printing | Yes | Mares Comercial Ltda, São Paulo, Brazil |
| PPC | USA-Folien | Laser printing | Yes | USA Folien Brazil Ltda, São Paulo, Brazil |
| PPC | Garra | Laser printing | Yes | Industria Brasileira de Audiovisual Ltda, Blumenau, Brazil |
| PPC | 3 M | Laser printing | Yes | 3 M do Brasil, São Paulo, Brazil |
| PET | Premium Mares | Inkjet printing | No | Mares Comercial Ltda, São Paulo, Brazil |
| PET | USA-Folien | Inkjet printing | No | USA Folien Brazil Ltda, São Paulo, Brazil |
| PET | Garra | Inkjet printing | No | Industria Brasileira de Audiovisual Ltda, Blumenau, Brazil |
| PET | 3 M | Inkjet printing | No | 3 M do Brasil, São Paulo, Brazil |
| PET | Bellimagem | Inkjet printing | No | |
| PET | Unknown | Inkjet printing | No | Dunort Papelaria, Cuiabá, Brazil |
| PET | Unknown | Inkjet printing | No | Coxipó Papelaria, Cuiabá, Brazil |
Figure 7Microscopic images of the parasites and blood cells in the thin blood smears prepared on glass slides (A, C) and on a transparent acetate sheet (B, D).
Figure 8Microscopic images of the parasites and blood cells in the thick blood smears prepared on glass slides (A) and on transparent acetate sheet (B).
Comparison of parasitic density ( infection) from thick blood smears prepared on different media according to the microscopists
| Glass slide | Mean | 10,260 | 9,822 | 8,540 |
| Variance | 63,616,000 | 69,581,045 | 53,139,333 | |
| Standard deviation | 7,976 | 8,342 | 7,290 | |
| Transparent acetate | Mean | 10,220 | 8,436 | 8,030 |
| Variance | 72,177,889 | 61,607,552 | 41,633,444 | |
| Standard deviation | 8,496 | 7,849 | 6,452 | |
| | p value* | 0.712 | 0.870 | 0.991 |
| p value** | 0.861 | 0.724 | 0.855 | |
*F-test (analysis of variance); **Bartlett test for equality of variance.