Literature DB >> 24935551

Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion.

Sekar Vadhana1, Balasubramanian SaravanaKarthikeyan1, Suresh Nandini2, Natanasabapathy Velmurugan1.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate and compare the cyclic fatigue resistance of RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and Mtwo (VDW, Munich, Germany) rotary files in continuous rotation and reciprocating motion.
METHODS: A total of 60 new rotary Mtwo and RaCe files (ISO size = 25, taper = 0.06, length = 25 mm) were selected and randomly divided into 4 groups (n = 15 each): Mtc (Mtwo NiTi files in continuous rotation), Rc (RaCe NiTi files in continuous rotation), Mtr (Mtwo NiTi files in reciprocating motion), and Rr (RaCe NiTi files in reciprocating motion). A cyclic fatigue testing device was fabricated with a 60° angle of curvature and a 5-mm radius. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture and the length of the broken fragments were recorded. All the fractured files were analyzed under a scanning electron microscope to detect the mode of fracture. The Kolmogorov-Smirnov test was used to assess the normality of samples distribution, and statistical analysis was performed using the independent sample t test.
RESULTS: The time taken for the instruments of the Mtr and Rr groups to fail under cyclic loading was significantly longer compared with the Mtc and Rc groups (P < .001). Scanning electron microscopic observations showed that the instruments of all groups had undergone a ductile mode of fracture. The length of the fractured segments was between 5 and 6 mm, which was not statistically significant among the experimental groups.
CONCLUSIONS: Mtwo and RaCe rotary instruments showed a significantly higher cyclic fatigue resistance in reciprocating motion compared with continuous rotation motion.
Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cyclic fatigue; nickel-titanium files; reciprocation; rotation

Mesh:

Substances:

Year:  2014        PMID: 24935551     DOI: 10.1016/j.joen.2013.12.010

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  11 in total

1.  Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study.

Authors:  Jesús Mena-Álvarez; Manuel Almanzor-López; Norberto Quispe-López; Ana De Pedro-Muñoz; Cristina Rico-Romano
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

2.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

3.  Comparison of vibration characteristics of file systems for root canal shaping according to file length.

Authors:  Seong-Jun Park; Se-Hee Park; Kyung-Mo Cho; Hyo-Jin Ji; Eun-Hye Lee; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2020-10-14

4.  Evaluation of the Fractured Surface of Five Endodontic Rotary Instruments: A Metallurgical Study.

Authors:  Mohsen Aminsobhani; Mohamad Saleh Khalatbari; Naghmeh Meraji; Abdollah Ghorbanzadeh; Ehsan Sadri
Journal:  Iran Endod J       Date:  2016

5.  Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation.

Authors:  Vadhana Sekar; Ranjith Kumar; Suresh Nandini; Suma Ballal; Natanasabapathy Velmurugan
Journal:  Eur J Dent       Date:  2016 Oct-Dec

Review 6.  Rotary science and its impact on instrument separation: A focused review.

Authors:  Sandhya Anand Khasnis; Prem Prakash Kar; Apoorva Kamal; Jayaprakash D Patil
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

7.  Influence of Continuous or Reciprocating Optimum Torque Reverse Motion on Cyclic Fatigue Resistance of Two Single-File Nickel-Titanium Rotary Instruments.

Authors:  Eugenio Pedulla; Giacomo Corsentino; Emanuele Ambu; Fabio Rovai; Federico Campedelli; Silvia Rapisarda; Giusy LA Rosa; Ernesto Rapisarda; Simone Grandini
Journal:  Eur Endod J       Date:  2017-08-22

8.  Resistance to torsional failure and cyclic fatigue resistance of ProTaper Next, WaveOne, and Mtwo files in continuous and reciprocating motion: An in vitro study.

Authors:  N O Varghese; Rajesh Pillai; U-Nu Sujathen; Shan Sainudeen; Abe Antony; Sinju Paul
Journal:  J Conserv Dent       Date:  2016 May-Jun

9.  Influence of three Ni-Ti cleaning and shaping files on postinstrumentation endodontic pain: A triple-blinded, randomized, controlled trial.

Authors:  Jogikalmat Krithikadatta; Vadhana Sekar; Paramanantham Sudharsan; Natanasabapathy Velumurugan
Journal:  J Conserv Dent       Date:  2016 Jul-Aug

10.  Micro-computed tomographic evaluation of the effect of the final apical size prepared by rotary nickel-titanium files on the removal efficacy of hard-tissue debris.

Authors:  Ke Xu; Juan Wang; Ke Wang; Nan Gen; Jin Li
Journal:  J Int Med Res       Date:  2018-03-27       Impact factor: 1.671

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.