Literature DB >> 24932989

A prospective randomized clinical evaluation of 3 presbyopia-correcting intraocular lenses after cataract extraction.

Jay S Pepose1, Mujtaba A Qazi2, Richard Chu3, Jason Stahl4.   

Abstract

PURPOSE: To compare contrast sensitivity, visual acuity (VA), and halos in subjects bilaterally implanted with 1 of 3 FDA-approved presbyopia-correcting intraocular lenses.
DESIGN: Prospective, randomized, partially masked, multicenter clinical trial.
METHODS: Seventy-eight subjects were randomized sequentially for bilateral implantation with the Crystalens AO (Bausch & Lomb Surgical), AcrySof IQ ReSTOR +3.0 (Alcon Laboratories), or Tecnis Multifocal (Abbott Medical Optics) lenses. Subjects were evaluated through visit 4 (4 to 6 months after surgery) with the following monocular and binocular assessments: high- and low-contrast VA, contrast sensitivity without glare, halos or starbursts, defocus curves, optical scatter, retinal point spread function, and safety.
RESULTS: The Crystalens AO and ReSTOR +3.0 demonstrated better monocular and binocular contrast sensitivity without glare at low to mid spatial frequencies compared with the Tecnis Multifocal lens. Binocular uncorrected distance VA was not significantly different between the 3 lenses. The Crystalens AO had significantly better binocular low-contrast distance-corrected VA than the ReSTOR +3.0 and better mean monocular low-contrast DCVA than the Tecnis Multifocal lens. The Crystalens AO demonstrated significantly better monocular and binocular uncorrected and distance-corrected intermediate VA than the ReSTOR +3.0 or Tecnis Multifocal lenses. The ReSTOR+3.0 lens had significantly better monocular and binocular uncorrected and distance-corrected near VA tested at 40 cm compared with the Crystalens AO and Tecnis Multifocal lens. The Crystalens AO elicited significantly less halos than the Tecnis Multifocal lens and less optical scatter than the ReSTOR +3.0 or Tecnis Multifocal lens.
CONCLUSIONS: The Crystalens AO had statistically better uncorrected intermediate VA and distance-corrected intermediate VA than the ReSTOR +3.0 or Tecnis Multifocal lenses and fewer photic phenomenon than the Tecnis Multifocal lens. Both multifocals had better distance-corrected near VA and uncorrected near VA than the Crystalens AO. These findings may guide intraocular lens selection for individual patients seeking to optimize vision at specific vergences or lighting conditions.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24932989     DOI: 10.1016/j.ajo.2014.06.003

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  7 in total

1.  Functional assessment of a new extended depth-of-focus intraocular lens.

Authors:  Giacomo Savini; Nicole Balducci; Claudio Carbonara; Scipione Rossi; Manuel Altieri; Nicola Frugis; Emilia Zappulla; Roberto Bellucci; Giovanni Alessio
Journal:  Eye (Lond)       Date:  2018-09-28       Impact factor: 3.775

2.  Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery: A Systematic Review and Bayesian Network Meta-analysis.

Authors:  Jeong-Yeon Cho; Yeo Kyoung Won; Jongyeop Park; Jin Hyun Nam; Ji-Yoon Hong; Serim Min; Nahyun Kim; Tae-Young Chung; Eui-Kyung Lee; Sun-Hong Kwon; Dong Hui Lim
Journal:  JAMA Ophthalmol       Date:  2022-09-22       Impact factor: 8.253

3.  Difference in Quality of Vision Outcome among Extended Depth of Focus, Bifocal, and Monofocal Intraocular Lens Implantation.

Authors:  Chen-Cheng Chao; Hung-Yuan Lin; Chia-Yi Lee; Elsa Lin-Chin Mai; Ie-Bin Lian; Chao-Kai Chang
Journal:  Healthcare (Basel)       Date:  2022-05-28

4.  Visual Function and Patient Satisfaction with Multifocal Intraocular Lenses in Patients with Glaucoma and Dry Age-Related Macular Degeneration.

Authors:  Carmen Sánchez-Sánchez; Laureano A Rementería-Capelo; Beatriz Puerto; Cristina López-Caballero; Aida Morán; José María Sánchez-Pina; Inés Contreras
Journal:  J Ophthalmol       Date:  2021-06-10       Impact factor: 1.909

5.  Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique.

Authors:  Abu-Bakar Zafar; Richard C Chu; Miranda N Bishara; Mujtaba A Qazi; Ashraf M Mahmoud; Jay S Pepose
Journal:  Clin Ophthalmol       Date:  2020-05-26

6.  Corneal Stromal Filler Injection as a Novel Approach to Correct Presbyopia-An Ex Vivo Pilot Study.

Authors:  Stefan Kassumeh; Jannik K Luther; Christian M Wertheimer; Katharina Brandt; Merle S Schenk; Siegfried G Priglinger; Andreas Wartak; Gabriela Apiou-Sbirlea; R Rox Anderson; Reginald Birngruber
Journal:  Transl Vis Sci Technol       Date:  2020-06-25       Impact factor: 3.283

7.  Development and Pilot Usefulness Testing of an Interactive Computerized Patient Decision Aid for Intraocular Lens Selection Before Cataract Surgery.

Authors:  Chong-Bin Tsai; Chien-Liang Fang; Ming-Shan Chen; Min-Yueh Yen; Chi-Yen Yeh; Zhi-Ming Lai; Mei-Ling Hsu; Shan-Tair Wang
Journal:  Patient Prefer Adherence       Date:  2022-01-25       Impact factor: 2.711

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.